Griddle Adjustments — GS Thermostat
Thermostatic Griddle Adjustments (GS Control)
GS Thermostat Calibration Instructions
1. Use a test instrument with a special disc type thermocouple or a reliable surface type pyrometer.
Note
A drop of oil on the face of the disc will provide better contact with the griddle plate.
2. Set all griddle thermostats to 350 deg F. In order to stablize the griddle temperature, you must cycle the
thermostats twice before taking a test reading.
3. Check the griddle temperature when the thermostat just cycles OFF by placing the thermocouple firmly on
the griddle surface directly above the sensing bulb of the thermostat.
5-3/4" (146.1mm)
11-13/16" (300mm)
18-3/4"(476.3mm)
35-7/16"(900mm)
FRONT
Place
Probe
Here
'ƌŝĚĚůĞ^ĞĐƟŽŶ
4. Take the reading and it should be between 335 deg F and 365 deg F. If the reading is outside of these limits,
calibrate as follows:
a. Carefully remove the dial without disturbing the
shaft position.
b. Hold the shaft steady and with a small flat screw
driver, turn the calibration screw located inside
the shaft clockwise to descrease temperature or
anit-clockwise to increase temperature.
Note
: Each 1/4 turn of the screw will create a
change of approximately 25 deg F.
c. Replace the thermostat dial and repeat steps 1
through 3 to verify that a correct adjustment has
been made.