A_GC_SM_HDGASCOUNTERSERV_GT-UT-SERIES (Rev 1)
Page 16
General Pilot Procedures (continued)
Griddles with SIT Thermostats
1. Turn thermostat control knob to the “
” (Figure 1) position. Then push in to engage the
flow of gas through the safety device to the pilot.
2. While holding the knob in, light pilot by pressing the red piezo lighter button or the black
igniter button if your model has the electric ignition option.
3. Continue to hold the knob in for 15 seconds after ignition, then release. Pilot should remain
lit.
4. If the pilot burner fails to light or does not stay lit, wait 5 minutes and repeat steps 1 to 3.
5. Turn the thermostat knob to the desired cooking temperature.
6. To shut down the main burner, turn the control knob to the “
” position.
Figure 1
Griddles with GS Thermostats
1. Ensure the individual on-off valve is in the off position.
2. Use the piezo, or electric spark if your model has this option, button(s) to ignite the pilot.
3. Once the pilot is lit, turn the thermostat knob to the desired cooking temperature.
4. To shut down, turn individual on-off valves to the off position.
Shutdown Procedure
To shutdown, turn all main burner valves to OFF position. If the appliance is to be shut down for a extended period
of time, close the pilot valves, (gum valve) by turning their set screws
fully
clockwise.
Shutdown Procedure on Griddles with SIT Thermostats
The Garland/US Range SIT thermostat control knob is configured to leave the pilot flame on continuously. The
knob is designed with a tab which will not permit complete pilot shutdown. In order to shutdown the griddle pilot
flame completely, you must perform Steps 1 to 3 below.
Note
There are no pilot valves (gum valve).
A
B
C
Hub
1. Turn griddle thermostat control knob to symbol “
” position and then
loosen the knob set screw (C). Gently pull knob off.
2. With the knob removed, push-down and turn the hub until the symbol (
•
) (B)
lines up with symbol
(A). With the hub in the position shown, the gas should
be off at the pilots and burners. There are no pilot valves (gum valve).
3. Finally, turn the manual valve on the main gas supply to the OFF position.
Pilot Flame On
Complete Shutdown