A_GC_SM_HDGASCOUNTERSERV_GT-UT-SERIES (Rev 1)
Page 10
T
hermostat C
o
ntr
olled Griddle M
odels
Technical Data
Model
Information
Garland Models
US Range Models
Model Information
GTGG24-GT24
UTGG24-GT24
Gas, Thermostatically Controlled Griddle, 24” Wide
GTGG36-GT36
UTGG36-GT36
Gas, Thermostatically Controlled Griddle, 36” Wide
GTGG48-GT48
UTGG48-GT48
Gas, Thermostatically Controlled Griddle, 48” Wide
GTGG60-GT60
UTGG60-GT60
Gas, Thermostatically Controlled Griddle, 60” Wide
GTGG72-GT72
UTGG72-GT72
Gas, Thermostatically Controlled Griddle, 72” Wide
Line
Ratings
Garland
US Range
Natural Gas @ 4.5”WC
Manifold Pressure
L. Propane Gas @ 10”WC
Manifold Pressure
Models
Models
BTU/h
Injectors#
BTU/h
Injectors#
GTGG24-GT24
UTGG24-GT24
64,000
#36
64,000
#51
GTGG36-GT36
UTGG36-GT36
96,000
#36
96,000
#51
GTGG48-GT48
UTGG48-GT48
128,000
#36
128,000
#51
GTGG60-GT60
UTGG60-GT60
160,000
#36
160,000
#51
GTGG72-GT72
UTGG72-GT72
192,000
#36
192,000
#51
For use with Natural or Propane gas only.
Gas input ratings shown for installation up to 2000 ft (610m) above sea level.
Supply Operating Pressure
Natural Gas
Propane Gas
“WC
MBar
“WC
MBar
7
17.5
11
27.5
GTGG36-GT36 Shown