1-28
8.
Release button to stop filling.
9.
“Continue Filling? Yes/No” is displayed.
10.
Press “NO” to exit.
FILL JUG FROM BULK:*
1.
When “Top Off Oil Empty” is displayed, the top-off jug is empty.
2.
To refill jug press and hold the orange reset button above the jug until the jug is full.
3.
Release the button to stop filling.
*NOTE: The jug may not fill if any of the following are in progress:
If FILTER NOW? YES/NO, CONFIRM YES/NO, or SKIM VAT is displayed, the fill jug button is
disabled until either a filter is complete or until no is chosen.
The system also checks these conditions. The following must be met before jug fill is allowed.
Solenoid closed
Orange fill button pressed longer than 3 sec.
Waste valve closed
Filter Now? Yes/No, Confirm Yes/No, or Skim Vat cannot be displayed
System power cycle (all boards – controllers, MIB, AIF and ATO) after changing setup from
JIB to Bulk (use momentary reset). Ensure reset is pressed and held for at least ten seconds.
No filtration or other filter menu selection can be in process.
Other factors that may not allow fill jug from bulk –
Defective solenoid
Defective switch
Bulk fresh oil pump issue
Bulk fresh oil relay issue
If using multiple fryer systems that are both attached to the bulk fresh oil system, they may not be
able to fill both units at the same time if they have a bulk fresh oil unit with a single head. Some
bulk fresh oil units have dual heads which can fill more than one fryer simultaneously.
1.14 AIF (Automatic Intermittent) Filtration Service Procedures
The AIF (Automatic Intermittent Filtration) board controls the
actuators that open and close the drain and return valve. The
AIF boards are located inside a protective housing under each
frypot (see Figure 13).
Figure 13
Содержание Frymaster FilterQuick FQE30
Страница 30: ...1 25 1 13 2 Bulk Wiring https appliancetechmanuals com ...
Страница 43: ...1 38 1 15 6 Menu Trees 1 15 6 1 FilterQuick Controller Setup Menu Tree https appliancetechmanuals com ...
Страница 44: ...1 39 1 15 6 2 FilterQuick Filter and Info Mode Menu Tree https appliancetechmanuals com ...
Страница 51: ...THIS PAGE INTENTIONALLY LEFT BLANK https appliancetechmanuals com ...