1-24
1.13
Bulk Service Issues
1.13.1 Bulk MIB Tests
The FilterQuick™™ fryer will ONLY operate with bulk systems that have the three-pole
float switch. If the float switch is the older two-pole switch, call the bulk oil provider.
These float switches are polarity specific which may short to ground and damage an
MIB board.
Normal measurements (MIB J6 8-pin connector with everything connected)
AC voltage measurements:
Pin 1 to Pin 2 - 24 VAC.
Pin 2 to Pin 8 - 24 VAC when waste tank is full, 0 VAC when it is not full.
Pin 2 to Pin 3 - 24 VAC when RTI fill pump is on, 0 VAC when it is off.
Using the bulk test box, PN# 108-0716 allows a quick and easy way to check the 24VAC, the waste
full switch and when the bulk fresh oil pump is operating.
Troubleshooting
All return and drain valves should be closed and pump should be off while the MIB is resetting. If any
of the valves or the pump is on during reset, the MIB board is bad or wires are shorted.
Bulk fresh oil pump is not operating or JIB is not filling:
See page 1-25 to ensure that no other function is taking priority over adding oil to jug.
1. Reset the power; wait 60 seconds and see if the valve opens.
With the JIB button pressed:
2. Voltage at MIB board from Pin 1 to Pin 2 should be 24 VAC; if not, check connections from bulk
fresh oil pump 24VAC transformer and check transformer.
3. Voltage at MIB board from Pin 1 to Pin 3 should be 24 VAC when filling JIB or vat; if not, the MIB
board is bad or wires to pump relay are shorted or both.
4. Voltage at Add pump relay should be 24 VAC; if not, check wiring from MIB board. The relay is
located at the fresh oil tank pump system.
5. Check voltage at ATO board on J8. Pin 9 to Pin 1 should be 24 VAC with the orange button
pressed.
Waste full signal:
Pin 2 to Pin 8 should be 24 VAC when full, 0 VAC when not full; if no voltage level change, the
connection from bulk oil waste switch or MIB board is bad.
Содержание Frymaster FilterQuick FQE30
Страница 30: ...1 25 1 13 2 Bulk Wiring https appliancetechmanuals com ...
Страница 43: ...1 38 1 15 6 Menu Trees 1 15 6 1 FilterQuick Controller Setup Menu Tree https appliancetechmanuals com ...
Страница 44: ...1 39 1 15 6 2 FilterQuick Filter and Info Mode Menu Tree https appliancetechmanuals com ...
Страница 51: ...THIS PAGE INTENTIONALLY LEFT BLANK https appliancetechmanuals com ...