Operation
Section 3
3-4
Part Number 020003315
1/11
1.
Incoming tap water
- should be at a minimum
dynamic pressure of 40 psi and maximum static
pressure of 70 psi.
2.
Carbonator Water pump motor -
Powers the water
pump. The water pump motor is part of the
carbonator pump deck.
3.
Carbonator Water pump -
Pumps tap water into the
carbonator tank. The water pump is part of the
carbonator. The incoming water for the carbonator
must be first run through the pump before
connecting to the proper cold plate inlet.
4.
Internal/External Carbonator tank -
Combines
CO
2
gas and tap water to form carbonated water.
The “carbonator” is the carbonator tank, water pump
and water pump motor.
5.
CO
2
cylinder -
Holds highly pressurized carbon
dioxide (CO
2
). The CO
2
cylinder is a steel or
aluminum cylinder tank. CO
2
gas flows through the
primary pressure regulator.
6.
BIB pressure gauge -
Set for 75 psi. Indicates CO
2
pressure going to B-I-B pumps.
7.
Primary pressure regulator -
Lowers the CO
2
gas
pressure, to 100 psi, so the CO
2
gas will be at the
proper pressure to enter the carbonator regulator.
8.
Lowered outgoing pressure -
Set for 75 psi.
Gauge indicates lowered outgoing pressure from the
CO
2
cylinder after being routed through the primary
pressure regulator at 100 psi.
9.
Secondary pressure regulator -
Lowers the CO
2
gas pressure before the CO
2
gas flows to the syrup
pump. CO
2
pressure activates the syrup pump.
10.
Syrup pump -
Draws syrup out of the bag-in-box
syrup package. Syrup flows through the syrup lines
to the dispenser for chilling, then dispensing. There
is a syrup pump for each bag-in-box syrup system.
11.
Bag-In-Box syrup cartons -
Box which contains a
plastic bag, filled with syrup.
RACKING
Regardless if you are working on a B-I-B or Figal
system, a place will be designated for placement of the
product. A rack (or shelf) system affords systematic
placement and complete usage of the beverage paid for.
The B-I-B rack allows the boxes to lay properly for syrup
dispersal. Please check with your B-I-B syrup supplier.
Some boxes must be slightly tilted down, while others
may be in virtually any position. The Figal tank rack
keeps the newer and full tanks organized at one end of
the beverage line with the partial tanks at the other.
B-I-B
The Bag-In-Box system refers to a plastic disposable bag.
The B-I-B normally contains 5 gallons of syrup, however
some locations offer 2-1/2 gallon B-I-B units. This plastic bag
is then held inside a cardboard or other container. B-I-B
systems are for post-mix applications only.
PUMPS
The syrup in a B-I-B system is delivered to the beverage
system through gas operated pumps. These pumps extract
the syrup out of the bags, forcing the syrup throughout the
system.
AUTO BAG SELECTORS
These are used on higher volume B-I-B systems where two
or more bags of the same product are connected to one
pump and one system. An auto bag selector is essentially a
valve that automatically changes from one bag (or series of
bags) to another bag (or series of bags) of syrup as the bags
empty, allowing a constant flow of product.
FRP-250 NON-ADJUSTABLE AGITATION TIMER
On units without selectable ice option, the timer is non-
adjustable and is set to agitate the ice for 3 seconds every
3.5 hours. Activating the dispenser will reset the timer. After
3.5 hours of non-use, the timer will energize the dispenser
motor.
The LED tells the technician in which mode the timer is
operating. Rather than a jumper pin, this timer has a female
spade connector that must be connected to terminal number 6.
When this jumper is in place, the LED will blink at one
second intervals, this is the run mode.
When the jumper is open, the LED will flash every
0.4 second. This is the test mode and the timer will cycle
every 55 seconds in test mode. If the timer is left in test
mode, it will automatically reset to run mode.
FRP-250SCI NON-ADJUSTABLE AGITATION
On units equipped with the selectable ice option, timed
agitaion for Flav’R-Pic units is handled by the control
board and is not adjustable.
NOTE: This timer is re-settable, timed agitation every
3.5 hours from last dispense or when the power supply
is broken.
1
RE
D
NO
2
3
6
4
5
COM
NC
Содержание Flav'R-Pic FRP-250
Страница 33: ...Section 3 Operation Part Number 020003315 1 11 3 9 NOZZLES FRP 250 FRP 250SCI Tubing Layout ...