![Manitowoc AJ-100CE Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/manitowoc/aj-100ce/aj-100ce_installation-operation-and-technical-manual_701294028.webp)
8 [203mm]
Drive Unit
60
1
4
[1530mm]
62
1
2
[1590mm]
29 [737mm]
6 [152mm]
8
1
2
[218mm]
21 [533mm]
25 [635mm]
12 [307mm]
25 [635mm]
10 [254mm]
C
B
4 [102mm]
8 [203mm]
L
M
23
1
2
[599mm]
10
1
4
[261mm]
47 [1194mm]
A
B
C
43 [1092mm]
75
1
2
[1919mm]
D
is
h C
learanc
e
31
1
4
[797mm]
6
1
2
[165mm]
6 [152mm]
26
1
2
[673mm]
Fr
ont
Vi
ew
Ri
ght
Si
de
67
1
4
[1707mm]
20
3
4
[527mm]
8
3
4
[222mm]
11
3
4
[298mm]
14
3
4
[375mm]
6 [152mm]
30 [763mm]
14 [357mm]
7
1
4
[185mm]
1
1
4
[
35mm]
K
J
H
G
T
abl
e to T
abl
e
O
v
eral
l
108 [2743mm]
36 [914mm]
64 [1626mm]
B
a
se
Un
it
Prew
as
h
118 [2997mm]
100 [2540mm]
F
loor Si
nk
Or D
rai
n
Wi
th 3" (76 mm)
Mi
ni
mum D
rai
n Li
ne
25 [637mm]
8 [204mm]
21 [535mm]
K
J
H
G
36 [914mm]
Right to Left
Legend to D
raw
ing
A - Mac
hi
ne w
ater i
nl
et 3/4" N
P
T
, 180°F
H
i-
temp,140°F
Low
-temp mi
ni
mum
B - El
ec
tri
c
al
c
onnec
ti
on
C
- D
rai
n c
onnec
ti
on 1-1/2" N
P
T
D
- Vent c
o
lla
r - Opti
onal
E - Vent c
ow
l s
tandard
F
- 3/4" N
P
T
180°F
Water Inl
et for w
as
h tank
f
ill,
f
inal rins
e,
& t
ank
heat
ing.
From gas
boos
ter heater. Interc
onnec
ti
ng hos
e
prov
ided by
manufac
turer.
G
- 3/4" N
P
T
140°F
Water i
nl
et for
gas
boos
ter heater.
H
- 3/4" N
P
T
180°F
Water Outl
et
c
onnec
ti
on to l
ine on di
s
h
mac
h
ine.
C
onnec
ti
on hos
e prov
ided by
manufac
turer.
J
- 3/4" N
P
T
G
as
C
onnec
ti
on
K - 4" O
D
Vent pi
pe c
onnec
ti
on. F
lue to
be i
n
s
tal
led to meet l
o
c
a
l c
odes
by
i
ns
tal
ling c
ontrac
tor.
L - Prew
as
h w
ater i
nl
et 3/4" N
P
T
110°F
-140°F
M - C
o
ld
w
a
ter thermos
tat pl
umbi
ng
c
onnec
ti
on 3/4" N
PT
- Opti
onal
N
ote: Al
l v
erti
c
al
di
mens
ions
are +/- 1/2" from
fl
oor due to adj
us
tabl
e bul
le
t feet.
4 [102mm]
7 [178mm]
D
E
8 [206mm]
24 [610mm]
Prew
as
h Pl
an Vi
ew
Sec
ti
on
wit
h
Co
ld
Wa
te
r Th
e
rmo
s
ta
t
16
3
4
[425mm]
16
1
4
[415mm]
L
M
3/4" [19 mm]
T
abl
e T
urndow
n
F
lange 3/4" Max
21" [533 mm]
Ra
ck Ra
il He
ig
h
t
Abov
e D
is
htabl
e
1/4" [6mm] - 5/16" [8mm]
Ra
ck Ra
il
Tu
b
T
abl
e
Us
e Silic
one Sealer
Betw
een T
abl
e and
Li
p of Mac
hi
ne to
Prev
ent Leak
age
R
e
c
o
mme
nde
d T
a
bl
e
F
a
br
ic
a
tion
No
te
: Tu
b
Will A
c
c
e
p
t
a T
abl
e F
lange
U
p
to 24 7/8"
[632 mm]
Drive Unit
Lef
t Si
de
66
1
2
[1692mm]
3 [79mm]
1
2
[
15mm]
84 [2134mm]
A
M
L
Wi
th D
oors
Open
R
ear of
Ma
ch
in
e
6 [152mm]
1 [25mm]
65
1
2
[1665mm]
34 [864mm]
4" (102 mm) wide x
16" (406 mm)
long c
u
tout i
n
Vent C
o
w
l/
Spl
a
s
h
Shi
el
d. Shi
pped w
it
h C
ov
er Pl
ate.
SECTION 1: SPECIFICATION INFORMATION
AJ-100 GAS - RIGHT TO LEFT
20
AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: 09-29-2007
Содержание AJ-100CE
Страница 9: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Страница 37: ...29 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...