![Manitowoc AJ-100CE Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/manitowoc/aj-100ce/aj-100ce_installation-operation-and-technical-manual_701294027.webp)
108 [
2743m
m
]
34 [
864m
m
]
8
1
2
[
218m
m
]
21 [
533m
m
]
25 [
635m
m
]
12 [
307m
m
]
25 [
635m
m
]
C
B
Dri
ve
Un
it
1
2
[1
5
mm]
84 [
2134m
m
]
A
M
L
Di
sh
Cl
e
a
ra
n
ce
W
it
h D
oors
Open
R
ear
of
Ma
ch
in
e
T
able t
o T
abl
e
Ov
er
al
l
6 [
152m
m
]
Left Side
Right Side
F
loor Si
nk
Or D
rai
n
W
it
h 3"
(76 m
m
)
M
inim
um
D
rai
n Li
ne
4"
(
102 m
m
) w
ide x
16"
(
406 m
m
)
long c
ut
out
in Vent
C
ow
l/
S
pl
as
h
Shield.
Shipped w
it
h C
ov
er
P
lat
e.
Mi
n
imu
m
Sc
rap
T
rough
14 [
355m
m
]
25 [
635m
m
]
21 [
533m
m
]
8 [
203m
m
]
64 [
1626m
m
]
36 [
914m
m
]
B
a
se
Un
it
Pr
ew
as
h
Left to Right
Prew
as
h Plan V
iew
S
ec
ti
on
wi
th
Co
ld
Wa
te
r Th
e
rmo
sta
t
16
3
4
[
425m
m
]
16
1
4
[
415m
m
]
L
M
3/
4"
[
19 m
m
]
T
abl
e T
urndow
n
F
lange 3/
4"
M
ax
21"
[
533 m
m
]
Ra
ck Ra
il He
ig
h
t
Abov
e D
is
ht
abl
e
1/
4"
[
6m
m
] - 5/
16"
[
8m
m
]
Ra
ck Ra
il
Tu
b
T
abl
e
U
s
e Silic
one S
eal
er
Bet
w
een T
abl
e and
Lip of
M
ac
hi
ne t
o
Pr
ev
ent
Leak
age
Recom
m
ended Tabl
e Fabr
icat
io
n
N
o
te
: T
u
b
W
ill Ac
c
e
p
t
a T
able F
lange
U
p t
o 24 7/
8"
[632 m
m
]
66
1
2
[
1692m
m
]
65
1
2
[
1666m
m
]
1 [
25m
m
]
65
1
2
[
1665m
m
]
100 [
2540m
m
]
116 [
2946m
m
]
32
3
4
[
833m
m
]
Dri
ve
Un
it
75
1
2
[
1918m
m
]
60
1
4
[
1529m
m
]
62
1
2
[
1590m
m
]
29 [
737m
m
]
10 [
254m
m
]
M
4 [
102m
m
]
24 [
609m
m
]
59
3
4
[
1519m
m
]
L
A
23
1
2
[
598m
m
]
6 [
152m
m
]
7 [
178m
m
]
D
E
B
33
1
2
[
851m
m
]
8 [
206m
m
]
14 [
356m
m
]
Mi
n
imu
m
10" H
ig
h
Tabl
e
B
a
ckspl
a
sh
Sc
ra
p
Tr
ough
6 [
152m
m
]
36 [
914m
m
]
31
1
4
[
795m
m
]
6
1
2
[
165m
m
]
26
1
2
[
673m
m
]
Front View
C
41 [
1040m
m
]
20
3
4
[
527m
m
]
8
3
4
[
222m
m
]
11
3
4
[
298m
m
]
14
3
4
[
375m
m
]
6 [
154m
m
]
30 [
763m
m
]
14 [
357m
m
]
7
1
4
[
185m
m
]
1
1
4
[3
5
mm]
F
H
G
J
K
H
G
J
K
Legend
A - M
ac
hine w
at
er inl
et
3/
4"
N
P
T
, 180°F
H
i-t
em
p,
140°F
Low
-t
em
p m
ini
m
um
B - Elec
tr
ic
al
c
onnec
ti
on
C
- D
rai
n c
onnec
ti
on 1-1/
2"
N
P
T
D
- Vent
c
ollar
-
Opt
ional
E - Vent
c
ow
l s
tandar
d
F
- 3/
4"
N
PT
180°F
W
at
er I
nlet
f
or
w
as
h t
ank
f
ill,
f
in
a
l
rins
e,
& t
ank
heat
ing.
F
rom
gas
boos
ter
heat
er
.
I
nt
er
c
onnec
ti
ng hos
e pr
ov
ided by
m
anuf
ac
tur
er
.
G - 3/
4"
N
PT
140°F
W
at
er
i
nl
et
f
or
gas
boos
ter
heat
er
.
H
- 3/
4"
N
PT
180°F
W
at
er
Out
let
c
onnec
ti
on t
o
line on dis
hm
ac
hine.
C
onnec
ti
on hos
e pr
ov
ided by
m
anuf
ac
tur
er
.
J
- 3/
4"
N
PT
Gas
C
onnec
tion
K - 4"
OD
Vent
pipe c
onnec
ti
on.
F
lue t
o be i
ns
tal
led
t
o m
eet
loc
al c
odes
by
i
ns
ta
lli
ng c
ont
rac
tor
.
L - Pr
ew
as
h w
at
er inlet
3/
4"
N
PT
110°F
-140°F
M
- C
old w
at
er t
her
m
os
tat
pl
um
bi
ng
c
onnec
ti
on 3/
4"
N
P
T
-
Opt
ional
N
ot
e:
All v
ert
ic
al dim
ens
ions
ar
e +
/-
1/
2"
f
rom
fl
oor due t
o adjus
tabl
e bul
let
f
eet
.
10
1
2
[
267m
m
]
SECTION 1: SPECIFICATION INFORMATION
AJ-100 GAS - LEFT TO RIGHT
19
AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: 09-29-2007
Содержание AJ-100CE
Страница 9: ...1 SECTION 1 SPECIFICATION INFORMATION ...