Provide an inspect able drainage pit on the floor connected with the sink drainage line, suitable for
receiving the machine gravity drainage tube. The drain tube must be positioned so that the water
flows out freely, without possibility for the pipe to clog up during the operation.
4.3 Water softener (optional)
The water softener for softening the mains water can be manual or automatic, depending on
customer’s request.
Before connecting the water softener to the coffee machine, the resins contained in it should
be washed of
f as described in the user’s manual supplied with the appliance.
Note:
The water softener is considered an essential device to guarantee a proper operation of the espresso
coffee machine. A water softening system should be provided in order to guarantee the efficiency,
performance and duration of the components in the machine.
4.4 Installation of water system
1) Use the pipe 2000 mm, provided with the machine to connect the cut-off valve of the mains to the
tap for water inlet to the bottom of the machine.
4.5 Installation of water system with motor pump (optional)
1) Use the pipe 2000 mm, provided with the machine to connect the machine to the pump.
4.6 Drain line
Connect the drainage tube to the grounds collecting tray and to the water drainage system.
4.7 Electrical connection
Instructions for a proper electrical connection of the espresso coffee machine:
•
Before connecting the unit to the electrical mains, make sure that the data on the data
plate corresponds to the electrical mains.
• The tag is located on the left side of the machine (and can be accessed by removing the lower tray).
• The electrical system provided by the client must comply with current standards. The power socket
must be equipped with a working earth connection. ACS-M&V S.r.l. will not in any way be held liable
if legal requirements are not met. An improper installation can cause injury or damage for which the
manufacturer cannot be held liable.
• For the electrical connection, it is necessary to install an unipolar main switch upstream of the power
supply; this switch should be rated according to the electrical characteristics (power and voltage)
shown on the rating tag. The unipolar switch must disconnect the power supply with a contact gap
of at least 3 mm.
• If it is necessary to use adapters, multiple plugs and extensions, only products meeting applicable
safety standards must be used.
• To avoid any overheating of the power cable, unwind it completely.