background image

10

1

22.5

0.0937

BLE

1

27.5

0.1363

BLE

2

26.1

0.1115

BLE

2

32.0

0.1622

BLE

2

27.7

0.1445

BLE

2

33.9

0.2102

BLE

2

29.2

0.1775

BLE

2

35.7

0.2582

BLE

2

30.7

0.2105

BLE

2

37.6

0.3062

BLE

3

34.2

0.2284

BLE

3

42.0

0.3322

BLE

3

35.7

0.2614

BLE

3

43.9

0.3802

BLE

3

38.8

0.3274

BLE

3

50.3

0.4762

BE

4

46.4

0.3782

BE

4

56.5

0.5501

BE

4

49.5

0.4442

BE

4

60.3

0.6461

BE

5

54.5

0.4950

BE

5

66.5

0.7200

BE

5

57.5

0.5610

BE

5

70.2

0.8160

BE

6

62.5

0.6118

BE

6

76.5

0.8899

BE

6

65.6

0.6778

BE

6

80.2

0.9859

BE

1

24.2

0.1079

BLE

1

29.1

0.1505

BLE

2

28.1

0.1284

BLE

2

34.0

0.1791

BLE

2

29.7

0.1664

BLE

2

35.9

0.2321

BLE

2

31.4

0.2044

BLE

2

37.9

0.2851

BLE

2

33.0

0.2424

BLE

2

39.9

0.3381

BLE

3

36.8

0.2630

BLE

3

47.2

0.3668

BE

3

38.4

0.3010

BLE

3

49.2

0.4198

BE

3

41.7

0.3770

BLE

3

53.2

0.5258

BE

4

49.8

0.4355

BE

4

59.9

0.6074

BE

4

53.1

0.5115

BE

4

63.8

0.7134

BE

5

58.5

0.5700

BE

5

70.5

0.7950

BE

5

61.8

0.6460

BE

5

74.5

0.9010

BE

6

67.2

0.7045

BE

6

81.1

0.9826

BE

6

70.5

0.7805

BE

6

85.1

1.0886

BE

1

25.8

0.1221

BLE

1

30.8

0.1647

BLE

2

30.0

0.1453

BLE

2

35.9

0.1960

BLE

2

31.8

0.1883

BLE

2

38.0

0.2540

BLE

2

33.5

0.2313

BLE

2

40.1

0.3120

BLE

2

35.3

0.2743

BLE

2

42.2

0.3700

BLE

3

39.4

0.2976

BLE

3

49.8

0.4014

BE

3

41.1

0.3406

BLE

3

51.9

0.4594

BE

3

47.3

0.4266

BE

3

56.1

0.5754

BE

4

53.1

0.4928

BE

4

63.2

0.6647

BE

4

56.7

0.5788

BE

4

67.4

0.7807

BE

5

62.5

0.6450

BE

5

74.5

0.8700

BE

5

66.0

0.7310

BE

5

78.7

0.9860

BE

6

71.8

0.7972

BE

6

85.8

1.0753

BE

6

75.4

0.8832

BE

6

90.0

1.1913

BE

Smoke  extraction  dampers  single  are  designed  to  remove  heat  and  combustion  products  (e.g.
smoke) from single fire compartment according EN1366-9.

 

Smoke extraction dampers  single are designed for installation with horizontal or vertical axis of the blades.

 

Backtoback smoke exhaust duct has to be hung or supported so as all load transfer from the  backtoback
smoke 

exhaust 

duct 

to 

the 

damper 

is 

absolutely 

excluded. 

To 

provide 

needed

access  space  to  the  control  device,  all  other  objects  must  be  situated  at  least  350  mm  from  the
control parts of the damper.

During  installation  the  damper  blade  must  be  in  position  CLOSED.  The  damper  body  should
not  be  deformed  in  the  course  of  installation.  Once  the  damper  built  in,  its  blade  should  not  grind
on the damper body during opening or closing.

Example, how to calculate effective area and size of SEDS-L damper [AxB], when knowing  air volume in [m

³

/s] or [m

³

/h] on damper.

Maximum allowed air velocity on SEDS-L is 12 [m/s].

Formula:

Q … air volume [m

³

/s]

Sef … effective free area of damper [m

²

]

v … air velocity on damper [m/s]

Example:

Air volume needed is 26000 m

³

/h

26000 / 3600 = 7,222 m

³

/s

7,222 / 12 = 0,602 m

²

 is min. effective free area [Sef]

Find the value Sef in the table 3.2.1. The effective are has to be the same or bigger. There will be more options of damper, sizes AxB.

Содержание SEDS-L

Страница 1: ......

Страница 2: ...for production designing ordering delivery maintenance and operation 1 Description 2 2 Design 3 3 Dimensions weights 8 4 Placement and Assembly 10 5 Pressure drops 12 6 Noise data 12 7 Material 14 8...

Страница 3: ...applications according with EN 1366 9 The field of direct applications based on tests results is acceptable according to EN 1363 1 part A 1 and A 2 EN 1366 2 part 13 and EN 1366 10 part 9 Smoke extrac...

Страница 4: ...r macroclimatic areas with mild climate according to EN 60 72133 Temperature in the place of installation is permitted to range from 20 C to 50 C Design with actuating mechanism SEDS L is equipped by...

Страница 5: ...II II Degree of protection IP 54 Running time for 95 30 s Ambient temperature range Non operating temperature 30 C 50 C 40 C 80 C Connecting motor auxiliary switch cable 1 m 3 x 0 75 mm cable 1 m 6 x...

Страница 6: ...imensioning 18 VA Imax 8 2 A 5 ms 15 VA Imax 7 9 A 5 ms Protection class III II Degree of protection IP 54 Running time for 95 60 s Ambient temperature range Non operating temperature 30 C 50 C 40 C 8...

Страница 7: ...the BKSE24 6 unit It also receives positioning commands from the control unit and triggers the actuator to the required position The last control command is retained troughout temporary power failure...

Страница 8: ...ed by the BKSE24 6 unit and evaluated individually All BKNE230 24 units are triggered simultaneously To BKSE24 6 can be connected max 6 BKNE230 24 Communication is via the 2 wire conductor Correct ope...

Страница 9: ...consumption 3 5 W operating position Dimensioning 5 5 VA 18 VA Imax 6 4 A 2 5 ms Protection class III Degree of protection IP 20 Ambient temperature range 0 50 C Connecting screw terminals for cable 2...

Страница 10: ...BE 5 44 5 0 3075 BE 5 38 5 0 1785 BE 5 47 0 0 3485 BE 6 41 6 0 1947 BE 6 50 9 0 3801 BE 6 43 6 0 2157 BE 6 53 4 0 4211 BE 1 15 9 0 0369 BLE 1 19 2 0 0653 BLE 2 18 3 0 0439 BLE 2 22 2 0 0777 BLE 2 19...

Страница 11: ...0 4928 BE 4 63 2 0 6647 BE 4 56 7 0 5788 BE 4 67 4 0 7807 BE 5 62 5 0 6450 BE 5 74 5 0 8700 BE 5 66 0 0 7310 BE 5 78 7 0 9860 BE 6 71 8 0 7972 BE 6 85 8 1 0753 BE 6 75 4 0 8832 BE 6 90 0 1 1913 BE Smo...

Страница 12: ...11 Installation examples Pozice 1 Damper hinge 2 Nut 3 Washer 4 Profile C 5 Washer C 6 Wall construction without fire resistance...

Страница 13: ...63 68 68 67 65 62 48 57 65 70 70 69 67 64 50 w air velocity in the free cross section AxB i e before blades f frequency of octave band Sound power level corrected with filter A ps static pressure drop...

Страница 14: ...67 65 62 48 w air velocity in the free cross section AxB i e before blades f frequency of octave band 13 21 26 26 25 23 20 6 21 29 34 34 33 31 28 14 28 36 41 41 40 38 35 21 34 42 47 47 46 44 41 27 38...

Страница 15: ...re must be in the range from 5 C to 40 C and maximum relative humidity 80 Dampers must be protected against mechanic damages when transported and manipulated All effective safety standards and directi...

Страница 16: ...case that dampers are found unable to serve for their function for any cause it must be clearly marked The operator is obliged to ensure that the damper is put into condition in which it is ready for...

Страница 17: ...mechanism BLE24 BE24 12 54 with the communication and supply device BKNE 230 24 and actuating mechanism BLE24 BE24 12 ST 66 insulation inside of the blades I flanges with height 20 mm F WEIGHT kg Dob...

Страница 18: ...reserves the right for innovations of the product For actual product information see www mandik com MAND K a s Dob sk 550 26724 Hostomice Czech Republic Tel 420 311 706 706 E Mail mandik mandik cz ww...

Отзывы:

Похожие инструкции для SEDS-L