![Man D2862 LE423 Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/man/d2862-le423/d2862-le423_operating-instructions-manual_699117077.webp)
Commissioning and operation
77
“Gearbox forwards / reverse" (lock) position
(2)
In this lever position, two different functions are possible.
1. Standard function:
The gearbox clutch is engaged to Forwards" or Reverse"; the power unit is idling.
2. “Increase engine speed" function
The Increase engine speed" function is set. The engine speed of the power unit is raised prior to enga
ging the clutch and after disengaging the clutch it is lowered again to idling speed. Between the clutch
engaging operations, individual delays (waiting periods BEFORE and AFTER clutch engaging) can be
set.
“Maximum engine speed" position
(3)
Position (3) shows the maximum engine speed" for the “Forward and Reverse Range". Between positions
(2) and (3) the engine speed can be set variably. The gearbox clutch is engaged to “Forward" or “Reverse".
Control panel - Control head for twin engine installations
6
7
8
9
10
11
1
4
5
2
3
(1) Button COM
(2) Button SYN
(3) Button TRL
(4) Button S&G
(5) Brightness sensor
(6) LED COMMAND
(7) LED WARM UP
(8) LED SYNCHRO
(9) LED TROLLING
(10) LED SLIP & GRIP
(11) LED ALARM
Содержание D2862 LE423
Страница 6: ...Declaration 6...
Страница 14: ...Commissioning and operation 14 Engine views V8 1200 D2868 LE433 2 3 4 5 6 7 8 9 1 10 11 10 12 3 8...
Страница 42: ...Commissioning and operation 42 Active alarm page Figure Alarms table Acknowledged alarm page...
Страница 131: ......
Страница 132: ...MAN Truck Bus AG Vogelweiherstra e 33 90441 N rnberg Germany A member of the MAN Group Printed in Germany 51 99493 8578...