Troubleshooting chart
16
x =
Probable
o =
Possible
1.
EDC self-diagnosis or flash code output
2.
Starter turns over engine only slowly or not at all
3.
Starter turns, engine does not start, engine does not start / difficult to start when cold
4.
Engine stalls (dies) during operation, no longer starts (starter turns), engine does not start / starts with difficulty when hot
5.
Sudden, temporary engine shut-down, engine does not reach full revs
6.
Engine only runs at idle speed, no throttle response
7.
Engine only runs at increased idle speed, no throttle response
8.
Rated engine speed distinctly reduced (even under no load)
9.
Reduced output in all ranges
10. Irregular engine operation, traction loss
11. Unstable idle speed, engine hunting, misfiring, knocking in engine
12. Engine judder
13. Unusual combustion noise
14. Excessive smoke emission: White smoke / blue smoke
15. Excessive smoke emission: Black smoke
16. Engine temperature too high (coolant loss)
17. Intermediate engine speed control cannot be activated / does not switch off,
engine revs too high
18. Fuel consumption too high
19. Lubricating oil pressure too low
20. Lubricating oil pressure too high
21. Lubricating oil consumption too high
22. Engine too loud / mechanical noise
Possible causes
x
Coolant level too low, air in coolant circuit
x
V-belt for water pump drive not tensioned correctly
x Incorrect V-belt tension
x
Water pump leaking, faulty / thermostat faulty, does not open
x
Coolant lines leaking, clogged or twisted
x
Coolant entering combustion chamber (cylinder head / gasket leaking)
x
Resistor bank EDC control unit pin 51
x
x x o
o
Power supply to EDC control unit interrupted or battery voltage too low /
Relay K1 faulty
x x o
o
Line terminal 15 to EDC control unit (pin 47) interrupted / loose contact
x
Line defective: Pin 23 or 41
x
o o o
EDC control unit faulty (internal fault)
x
x x x
o o
o x
Incorrect EDC control unit (check MAN part number)
x x
o
Intermediate engine speed activated
x
EOL programming terminated / voltage interrupt
x
Afterrunning not completed (e.g. shut-down via EMERGENCY STOP)
x
EOL programming: configuration incorrect
x
Engine bearings worn
Содержание D 2866 LUE 605
Страница 1: ......
Страница 2: ......
Страница 14: ...Notes 12...
Страница 19: ...Memoranda 17...
Страница 20: ...Engine views 18 Engine views 3 4 2 1 7 6 5 8 11 10 9...
Страница 68: ...Memoranda 66...
Страница 133: ...131 Service Data...
Страница 157: ...155 Special tools...
Страница 158: ...Special tools 156 2 3 4 5 6 7 8 1 6 1 6 2 6 3 9 1 9 2 9 3 9...
Страница 160: ...Special tools 158 10 11 16 14 14 1 12 13 18 18 1 12 1 12 2 15 5 15 4 15 1 15 1 15 2 15 3 15 3 15 6 15 7 15 17...
Страница 162: ...Special tools 160 21 22 25 25 2 24 25 1 26 27 1 27 2 27 20 1 19 2 19 1 20 2 19 20 23 28...
Страница 164: ...Special tools 162 30 31 32 1 32 32 2...
Страница 167: ...Special tools 165 Pressing mandel for cap dia 62 1 mm Pressing mandel for cap dia 50 1 mm...
Страница 170: ...Notes 168...
Страница 173: ......
Страница 174: ......