Side
Parameter Min. Typ. Max. Unit
Power supply: Voltage D.C 10 13 13.8 V (dc)
Current (100 mW) 100 mA
Transmitted power (link out) rms (50 Ohms) 80 90 100 mW
Technical Specifications
How to open the JACK R:
Use the allan key inserted into the grub screw to remove the antenna socket.
1A FUSE
fig. 1
BATTERY or
EXTERNAL SUPPLY:
10/13.8V DC
300 mA(MINIMUM)
I
S
EXT
TST
Top view
A
For PERMANENT Power Supply
Jumper A = IN Jumper B= OUT
B
1 2 3 4
White
Blue
Green
Yellow
Antenna Socket
RX
+
-
Top
NB: When closing, make sure that the cover is properly seated and that the antenna
socket is tightened for good contact.
Power Connection
12v dc supply is permanently
connected to the unit. Contacts
are connected to the 4 inputs
and each channel is triggered
by applying power to the input.
0
= INPUT 1 - TRANSMISSION ON ACTIVATE ONLY
INPUT RESTORE REGISTER
(option 03)
(3)
(0)
0
0
0
0
1
2
3
4
1 = INPUT 1 TRANSMISSION ON ACTIVATE AND RESTORAL
S
I
S
I
Now press 4 zeroes ( ) or ones ( ) to select which inputs will TRIGGER and RESTORE
S
I
I
0
= INPUT 2 - TRANSMISSION ON ACTIVATE ONLY
1 = INPUT 2 TRANSMISSION ON ACTIVATE AND RESTORAL
0
= INPUT 3 - TRANSMISSION ON ACTIVATE ONLY
1 = INPUT 3 TRANSMISSION ON ACTIVATE AND RESTORAL
0
= INPUT 4 - TRANSMISSION ON ACTIVATE ONLY
1 = INPUT 4 TRANSMISSION ON ACTIVATE AND RESTORAL
0
= INPUT 1 - POSITIVE TRIGGER (AP12V)
N/O OR N/C INPUT REGISTER
F
ACT
OR
Y
DEF
AUL
T
(option 04)
(4)
(0)
0
0
0
0
1
2
3
4
S
I
S
I
Now press 4 zeroes ( ) or ones ( ) to select which inputs are N/O and which are N/C
S
I
I
1
= INPUT 1 - NEGATIVE TRIGGER ( REMOVING 12V)
0
= INPUT 2 - POSITIVE TRIGGER (AP12V)
1
= INPUT 2 - NEGATIVE TRIGGER ( REMOVING 12V)
0
= INPUT 3 - POSITIVE TRIGGER (AP12V)
1
= INPUT 3 - NEGATIVE TRIGGER ( REMOVING 12V)
0
= INPUT 4 - POSITIVE TRIGGER (AP12V)
1
= INPUT 4 - NEGATIVE TRIGGER ( REMOVING 12V)
I
F
ACT
OR
Y
DEF
AUL
T
0
= INPUT 1 DETECTION TIME = 0.3 SEC.
INPUT DETECTION TIME
F
ACT
OR
Y
DEF
AUL
T
(option 05)
(5)
(0)
0
0
0
0
1
2
3
4
S
I
S
I
Now press 4 zeroes ( ) or ones ( ) to select which inputs have a delayed detection
S
I
I
I
0
= INPUT 2 DETECTION TIME = 0.3 SEC.
0
= INPUT 3 DETECTION TIME = 0.3 SEC.
0
= INPUT 4 DETECTION TIME = 0.3 SEC.
1
= INPUT 1 DETECTION TIME = 20 SEC.
1
= INPUT 2 DETECTION TIME = 20 SEC.
1
= INPUT 3 DETECTION TIME = 20 SEC.
1
= INPUT 4 DETECTION TIME = 20 SEC.
I
only applicable with constant power applied
only applicable with constant power applied
To program inputs 3 and 4 trigger from Positive(N.O.) to Negative (N.C.)
Hold both the and the buttons until the green and red LED flash continuously
then select the option number (04)
follow with two zeroes and two ones:
S
I
(4)
(0)
S
S
I
I
I
I
S
S
I
I
(0)
(0)
(1)
(1)
The on board LED’s will indicate the progress and the completion of each task
M000050
3