background image

Side

Parameter                                        Min.     Typ.     Max.     Unit

    Power supply: Voltage  D.C                                 10         13      13.8     V (dc)
                           Current (100 mW)                                     100                  mA  
                           

    Transmitted power  (link out) rms (50 Ohms)       80        90       100      mW

Technical Specifications

How to open the JACK R:

 Use the allan key inserted into the grub screw to remove the antenna socket.

1A FUSE

fig. 1

BATTERY or
EXTERNAL SUPPLY:
10/13.8V  DC
300 mA(MINIMUM)

I

S

EXT

TST

Top view

A

For PERMANENT Power Supply
Jumper A = IN    Jumper B= OUT

B

1  2  3  4

 White

 Blue

 Green

 Yellow

Antenna Socket

RX 

+

 

Top

NB: When closing, make sure that the cover is properly seated and that the antenna 
        socket is tightened for good contact.

      

 Power Connection

       12v dc supply is permanently 
       connected to the unit. Contacts 
       are connected to the 4 inputs 
       and each channel is triggered 
       by applying power to the input.

0

 = INPUT 1  - TRANSMISSION  ON  ACTIVATE ONLY

INPUT RESTORE  REGISTER

(option 03)

(3)

(0)

0

0

0

0

1

2

3

4

1 =  INPUT 1 TRANSMISSION  ON  ACTIVATE  AND  RESTORAL

S

I

S

I

Now press 4  zeroes (        ) or  ones (       ) to select which inputs will TRIGGER and RESTORE

S

I

I

0

 = INPUT 2  - TRANSMISSION  ON  ACTIVATE ONLY

1 =  INPUT 2 TRANSMISSION  ON  ACTIVATE  AND  RESTORAL

0

 = INPUT 3  - TRANSMISSION  ON  ACTIVATE ONLY

1 =  INPUT 3 TRANSMISSION  ON  ACTIVATE  AND  RESTORAL

0

 = INPUT 4  - TRANSMISSION  ON  ACTIVATE ONLY

1 =  INPUT 4 TRANSMISSION  ON  ACTIVATE  AND  RESTORAL

0

 = INPUT 1  - POSITIVE TRIGGER (AP12V) 

N/O OR N/C INPUT  REGISTER

F

ACT

OR

Y

 

DEF

AUL

T

(option 04)

(4)

(0)

0

0

0

0

1

2

3

4

S

I

S

I

Now press 4 zeroes (        ) or  ones (       ) to select which inputs are N/O and which are  N/C

S

I

I

1

 = INPUT 1  - NEGATIVE TRIGGER ( REMOVING 12V) 

0

 = INPUT 2  - POSITIVE TRIGGER (AP12V) 

1

 = INPUT 2  - NEGATIVE TRIGGER ( REMOVING 12V) 

0

 = INPUT 3  - POSITIVE TRIGGER (AP12V) 

1

 = INPUT 3  - NEGATIVE TRIGGER ( REMOVING 12V) 

0

 = INPUT 4  - POSITIVE TRIGGER (AP12V) 

1

 = INPUT 4  - NEGATIVE TRIGGER ( REMOVING 12V) 

I

F

ACT

OR

Y

 

DEF

AUL

T

0

 = INPUT 1   DETECTION TIME =  0.3  SEC.

INPUT  DETECTION  TIME

F

ACT

OR

Y

 

DEF

AUL

T

(option 05)

(5)

(0)

0

0

0

0

1

2

3

4

S

I

S

I

Now press 4 zeroes (        ) or  ones (       ) to select which inputs have a delayed detection

S

I

I

I

0

 = INPUT 2   DETECTION TIME =  0.3  SEC.

0

 = INPUT 3   DETECTION TIME =  0.3  SEC.

0

 = INPUT 4   DETECTION TIME =  0.3  SEC.

1

= INPUT 1   DETECTION TIME =  20 SEC.

1

= INPUT 2   DETECTION TIME =  20 SEC.

1

= INPUT 3   DETECTION TIME =  20 SEC.

1

= INPUT 4   DETECTION TIME =  20 SEC.

I

only applicable with constant power applied

only applicable with constant power applied

To program inputs 3 and 4  trigger from Positive(N.O.) to Negative (N.C.)

Hold both  the          and the        buttons  until the green and red LED flash continuously

then select the option number (04)

follow with two zeroes and two ones:                                        

S

I

(4)

(0)

S

S

I

I

I

I

S

S

I

I

(0)

(0)

(1)

(1)

The on board LED’s will indicate the progress and  the completion of each task

M000050 

3

Отзывы: