FAULT
CODE
STATE
DESCRIPTION
POSSIBLE CAUSES
281
Cold Wash Run
Low Water Level during wash
Low pump water flow, blocked spray nozzles,
Faulty solenoid, Panel lockout switches J8 open
circuit. Faulty level probe. Incorrect spray
nozzles fitted
282
Cold Wash Run
Door Open
Door opened during wash cycle, faulty door
interlock switch J11 J10
283
Cold Wash Run
Pump run without solenoid
Check Cycle Times parameters, Faulty solenoids
284
Cold Wash Run
Timeout before Level reached
Low pump water flow, blocked spray nozzles,
Faulty solenoid, Panel lockout switches J8 open
circuit. Faulty level probe. Door interlock
switch J11 J10
300
Hot Wash+Det Fill
Water Level Sensor Fail
Dirty Conductivity Sensor Probe, faulty
connections, faulty conductivity module
301
Hot Wash+Det Fill
Water Fill Timeout during detergent
Water Level Sensor Failed or Water supply low
flow, Water Fill solenoid failed, water supply
off
302
Hot Wash+Det Fill
Detergent Timeout
Faulty flow sensor, Faulty connections, blocked
tubing, faulty or blocked detergent pump,
Empty detergent bottle
304
Hot Wash+Det Fill
Water Heating Timeout
Failed Heater Element, heater circuit breaker
tripped, Faulty temp probe. Element over temp
cutout tripped, Panel lockout switches J8 open
circuit. Low water temperature Door interlock
switch J11 J10
305
Hot Wash+Det Fill
Water Heating Low Level
Water Leakage, faulty wash solenoid, faulty
level probe. Faulty connections, faulty
conductivity module
321
Hot Wash+Det Run
Low Water Level during wash
Low pump water flow, blocked spray nozzles,
Faulty solenoid, Panel lockout switches J8 open
circuit Faulty level probe. Incorrect spray
nozzles fitted
322
Hot Wash+Det Run
Door Open
Door opened during wash cycle, faulty door
interlock switch J11 J10
323
Hot Wash+Det Run
Pump run without solenoid
Check Cycle Times parameters, Faulty solenoids
324
Hot Wash+Det Run
Timeout before Level reached
Low pump water flow, blocked spray nozzles,
Faulty solenoid, Panel lockout switches J8 open
circuit. Faulty level probe. Door interlock
switch J11 J10
340
Hot Rinse Fill
Water Level Sensor Fail
Dirty Conductivity Sensor Probe, faulty
connections, faulty conductivity module
341
Hot Rinse Fill
Water Fill Timeout
Water Level Sensor Failed or Water supply low
flow, Water Fill solenoid failed, water supply
off
344
Hot Rinse Fill
Water Heating Timeout
Failed Heater Element, heater circuit breaker
tripped, Faulty temp probe. Element over temp
cutout tripped, Panel lockout switches J8 open
circuit. Low water temperature, Door interlock
switch J11 J10
345
Hot Rinse Fill
Water Heating Low Level
Water Leakage, faulty wash solenoid, faulty
level probe. Faulty connections, faulty
conductivity module
361
Hot Rinse Run
Low Water Level during wash
Low pump water flow, blocked spray nozzles,
Faulty solenoid, Panel lockout switches J8 open
circuit. Faulty level probe. Incorrect spray
nozzles fitted
Содержание WDS Series
Страница 43: ...WDS Operation Maintenance and Installation Manual Issue 11 Page 42 14 02 2019 6 3 Wiring Diagram 1ph devices...
Страница 44: ...WDS Operation Maintenance and Installation Manual Issue 11 Page 43 14 02 2019 6 4 Wiring Diagram 3ph devices...
Страница 54: ...Manufactured by Malmet Australia ABN 95 001 717 791 www malmet com au Part No 92 2226...