18
MAINTENANCE AND CLEANING
Cleaning the tank:
After working or when the tank is full of dust/liquid, which significantly decreases the
suction power, remove the plug from the electrical outlet and clean the drum. To do this,
unhook the two locks and remove the suction unit and the filter. Remove the filter and
clean the dust/liquid from the tank.
1
2
3
4
5
TECHNICAL DATA
Rated voltage (V)
220-240V~
Frequency (Hz)
50/60
Capacity (L)
45
Power Piec (W)
1500
Suction power end of tube (W)
219
Air flow rate (L/min)
1800
Vacuity (kPa)
18
Vacuum (mbar)
190
Sound power level (dB(A))
IEC 60704
Lpa=76
Tank capacity (L)
43.7
Dust bag capacity (L)
31.8
Hose length (m)
2.5
Hose diameter Ø (mm)
35
Tube holder
metal tube
Dims LxWxH (cm)
36.5x36.5x81.5
Weight (kg)
12
Connection cable
4 m, H05VV-F 3G1.5 mm²
Maximum load of
appliance outlet (W)
2000
IP rating
IPX4