12" Minimum

Sill/Support

12" Minimum

12" Of Brick From Liner

To Combustibles

Header

5/8" Fireclay Liner
Minimum or Equivalent

2" Clearance From Studs
To Chimney Wall

MASONRY THIMBLE

Figure 4

Masonry Chimney

If  using  a  masonry  chimney,  it  must  meet  the  minimum  standards  of  the  National  Fire  Protection
Association (NFPA) Standard 211.  The chimney must have at least a 5/8" fire clay liner or a listed chimney
liner system.  The chimney must be inspected for cracks, loose mortar, or any other signs of deterioration.
It is best to have the chimney inspected by a professional.  Make certain the chimney is cleaned prior to
installation of this fireplace.

The size of the chimney should be between 36 and 96 square inches.  Larger chimneys should be relined
to meet these requirements.  Incorrect sizing of the chimney may affect the draft and result in poor fireplace
performance.  Do not install more than one appliance to any chimney.

There  are  different  accepted  methods  of  connecting  the  fireplace  to  a  masonry  chimney  through  a
combustible  wall.    This  type  of  installation  requires  the  use  of  a  thimble  to  protect  the  surrounding
combustible materials.  Check with your local building officials or consult NFPA211.

Содержание Imperial Carousel

Страница 1: ...is necessary to get a somewhat dry mixture to much water in the mix may cause the refractory to crack exces sively and will reduce the strength of the refractory To test for proper water content cut vertically into the mixture with the trowel push the trowel sideways to open a 3 inch deep by 2 inch wide cut in the mixture then slide the trowel back up out of the cut The cut should stay open with v...

Страница 2: ...terialon one edge These pieces go on either side of thedoor Makecertainthatthesetwopieces are placed completly into the channel on either side of the door Failure to do this will maketherestoftheglassinstallationimpos sible 7 First loosen the glass retainers This is a metal strip secured by one screw in the middle Start with the left door panel The gasketmustbeontherightsideofthepanel 8 Slide the ...

Страница 3: ...e chimney the measurement is 63 from the backwall and 63 to the sidewall See figure 1 page 2 For corner installation the center of the chimney is 63 See figure 2 page 2 Clearance to Non combustibles The Imperial clearance to a combustible wall may be reduced with proper wall protection Accepted methods for wall protection would allow reduction of the wall clearances For appearance if desired a non...

Страница 4: ...48 54 16 Figure 3 54 Diameter Circle Hearth 8 Minimum is measured from the fire box 8 8 8 16 From Door Simpson Dura Vent Chimney System It is required to use a Dura Vent Universal Connector part number 8874 to install the chimney connector 1 The universal connector is installed into the support box The 8 x 30 slip pipe is then connected to the universal connector 2 The 8 x 30 starter pipe section ...

Страница 5: ...tion method of installing the connector pipe with the male end down allows for any moisture to remain on the inside of the connector pipe IMPORTANT THE SINGLE WALLCONNECTOR PIPE MUST NEVER PASS THROUGH A COMBUSTIBLE CEILING OR WALL At first glance you may become concerned that smoke will escape the pipe and enter the room This is not how the system will work The vacum in the chimney system will al...

Страница 6: ...gns of deterioration It is best to have the chimney inspected by a professional Make certain the chimney is cleaned prior to installation of this fireplace The size of the chimney should be between 36 and 96 square inches Larger chimneys should be relined to meet these requirements Incorrect sizing of the chimney may affect the draft and result in poor fireplace performance Do not install more tha...

Страница 7: ...g when using this or any other wood burning appli ance A partially open window or outside air register in the vicinity of the unit would be accept able Combustion air must be supplied in con formance with the Uniform Mechanical Code Imperial Carousel Page 7 7 CAUTION NEVERUSEGASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHAR COAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THI...

Страница 8: ...ote has accumulated it should be removed to reduce the chance of a chimney fire HOW TO REMOVE CREOSOTE 1 Clean the chimney with brushes and equipment available at local fireplace shops 2 Chemical chimney cleaners are used by adding them to the fire but they are not intended for use in chimneys already containing heavy soot deposits Rather they are intended to inhibit soot buildup They can be used ...

Отзывы: