Starter Section Fits
Into Hood
Hood
Slip Connector. Sheet
Metal Screw to
Chimney Connector.
Single Wall Chimney
Adapter
Insulated Class "A"
Chimney System
Dura-Vent Universal Adapter,
Security UP Adapter, Metalbe-
stos DS-CPA ,Or Single Wall
Chimney Adapter
Slip Connector
Sheet Metal
Screw
Support Box
Ceiling
Insulated Pipe
Imperial Carousel - Page 5
The above illustration represents the installation procedure for dripless pipe installation. This installation
method of installing the connector pipe with the male end down allows for any moisture to remain on the
inside of the connector pipe.
IMPORTANT: THE SINGLE WALL CONNECTOR PIPE MUST NEVER PASS
THROUGH A COMBUSTIBLE CEILING OR WALL.
At first glance you may become concerned that smoke will escape the pipe and enter the room. This is
not how the system will work. The vacum in the chimney system will always pull air into the chimney. If
you experience a downdraft with your installation it indicates that additional chimney height or a specialty
draft cap be added to your chimney system. Contact your dealer for further information regarding