Description and Function

The wetness Sensor consists of a small Transmitter (Tx) and a portable Receiver
(Rx).  The Tx is powered by 2 X AAA alkaline batteries. The Rx is powered either
by 4 X AA Alkaline batteries or via a 6 Volt power supply (not supplied). The Tx
can be attached to the supplied Easy-Clip Sensor or to Standard sensor or to a
Bed-Mat (optional extra). They can be placed inside a sanitary pad or nappy or
between the sheets under the user so that the Tx is triggered as soon as it
detects urination or wetness. Once triggered, a signal is sent to the Rx which will
emit a choice of alarm sounds, music or a recorded message, user’s name
(useful for identifying the wet user by name)  or music of choice indicating
urination or wetness. A silent vibrating option is available. Up to 16 Tx/Rx units
can be used in the same location and more than one Rx for each Tx.

The transmit range of the Tx to Rx is approximately 25 meters in open field and
fresh batteries.

The average battery life in the Tx is about 30 days and in the Rx about 7 days
(depending on the frequency and nature of alarms).

Transmitter (Tx)

Power
Place two AAA Alkaline batteries in the battery compartment and observe correct
polarity.  Average battery life is about 30 days.
Red LED Indicator
The Red LED should start to flash once every 5 seconds when sensor is dry and
once every one second when sensor is wet. Make sure batteries are new and
making  good contact within battery compartment if Red LED does NOT flash.
Encode Switch
Make sure that the encode switch setting inside the battery compartment is set in
a matching way to the Receiver (Rx) encode switch setting. 
Operation
If the Tx is used with Easy-Clip Sensor, then it can be attached to the user
pyjama top or night dress using the safety pin or the clip. If the Tx is being used
with a Bed-Mat, then the Tx should be attached to the side of the bed and away
from any wetness.

Receiver (Rx)

Power
Place four (4) AA Alkaline batteries in the battery compartment and observe
correct polarity.

6

Instruction booklet MO7  1/4/03  8:56 am  Page 6

Содержание MO7

Страница 1: ...annels 433MHz Please read the instructions carefully before use For best results and trouble free operation all instructions must be adhered to and followed Caution The wetness Sensor is not intended to replace proper adult supervision Instruction booklet MO7 1 4 03 8 56 am Page 1 ...

Страница 2: ...sh on Rx once every 5 seconds Make sure batteries are new and making good contact inside compartment if LEDs do not flash Record user s name or personal message or music if you wish or select type of alarm See diagram 5 Plug in Easy Clip Sensor make sure leaver is lifted open Standard Sensor or Bed Mat both optional extra to Tx The Easy Clip Sensor can be attached to the outside of close fitting p...

Страница 3: ...ton on the Rx If you do not remove the Tx sensor from wetness the Rx will alarm again in 3 minutes 9 Record the event time if you wish 10 Setup the Tx sensor again as in 5 above 11 To test the Tx Rx close the Easy Clip leaver or place a moist cloth across the Sensor or Bed Mat tracks The Rx should always Alarm allow up to 13 seconds for the Rx to alarm Battery saving feature 12 The transmitter ran...

Страница 4: ... a freshly made bed as before for reuse 7 Adjust the loudness of the sound with the volume control Hints The rest button will stop the Rx from sounding only for 3 minutes if the Bed Mat is not disconnected from the Tx The Bed Mat positively locks to the Tx to prevent accidental disconnection However it must be unlocked before attempting to reset the alarm on the Rx Please use a thicker cotton shee...

Страница 5: ...y to indicate urination so that the child patient is changed This releases the nursing staff from regular and frequent manual checking and can avoid the complications associated with child patient remaining wet until discovered 2 To develop a toileting regime by tabulating the child patient urination times a bladder activity pattern can be observed and the need for a bed pan or toilet anticipated ...

Страница 6: ... in open field and fresh batteries The average battery life in the Tx is about 30 days and in the Rx about 7 days depending on the frequency and nature of alarms Transmitter Tx Power Place two AAA Alkaline batteries in the battery compartment and observe correct polarity Average battery life is about 30 days Red LED Indicator The Red LED should start to flash once every 5 seconds when sensor is dr...

Страница 7: ...s no power make sure batteries are fresh and making good contact within battery compartment or Rx is out of range from the Tx 3 mm Red LED This LED will be ON as soon as batteries are inserted or power connected It will be OFF once signal is received from the Tx this can be up to 13 seconds long Flash when signal received from the Tx is getting weak Distance between Tx Rx is reaching normal operat...

Страница 8: ...mitting Wet signal The vibrating socket It is always ON when there is WET signal received When the vibrating motor unit optional Extra is connected to the receiver the motor will turn on regardless of the position of sound light selection switch Encode Switch A choice of 16 channels to avoid interferance and allow the use of more than one Tx Rx unit in the same location Please make sure that encod...

Страница 9: ...he Tx and Rx are both battery powered Batteries are already fitted free of charge To save battery the Rx can also be powered via a 6V DC ve centre pin mains adaptor not supplied Remove isolating tags from battery compartments if present Cleaning The Rx and Tx can be cleaned by wiping with a moist cloth Range The transmitter range is about 25 meters in open field Range may be reduced inside buildin...

Страница 10: ...ow TX Battery low Weak signal flash out of range ON beep sound OPEN 4 3 2 1 Sensor Socket Use 2 x AAA Alkaline batteries Please observe correct polarity when replacing batteries 4 3 2 1 On Transmitter Tx code switch inside battery compartment Make sure the settings are matching in both Tx and Rx Rx Tx Standyby Flash once 5 secs Alarm Flash once sec Instruction booklet MO7 1 4 03 8 56 am Page 10 ...

Страница 11: ... Remove Cover settings must match in Tx and Rx On 1 Sound LED MOTOR 2 LED MOTOR No sound Record Button output must be on1 message above Press and hold down during recording max 10sec DC 6C Power in Not supplied External Vibrator optional Extra Lift to remove belt clip Rx 1 2 3 Output 1 Messages 2 Sounds inbuilt 3 Melody 1 2 3 Sound selections 1 8 Sounds built in 2 Sound 1 built in 3 Sound 2 built ...

Страница 12: ...ical 10 Willow Holt Lowdham Nottingham NG14 7EJ England UK Tel 44 0 115 966 4440 Fax 44 0 115 966 4672 E mail malem malem co uk Web www malem co uk Malem Medical 2003 Instruction booklet MO7 1 4 03 8 56 am Page 12 ...

Отзывы: