3. OPERATION INSTRUCTIONS 

 
Fill the Blizzard 1200 with MLB snow liquid or other dealer recommended 
liquid to the maximum level mark shown on its tank. The machine can 
be controlled through a wired controller, a wireless remote, or a DMX 
console.  
 
A fan speed switch at the back of the machine sets two different fan 
speed level (Min, or Max). 
 
Important: Always monitor tank fluid level during operation. Running a 
snow machine with no fluid can permanently damage the unit.   
 
 
3.1 Wired Controller 
The wired controller come with a linear output knob for volume control. 
Output would start at ¾ of the way, and will reach 100% at maximum 
level.  
The wired controller come with a 5 meter long lead. 

 
3.2 Wireless Remote 

Attach the receiver’s magnetic base to the machine. Plug the 
receiver’s cable into the machine’s remote control input. Using the 
sending unit, your Blizzard 1200 can be operated from a distance of up 
to 50 meters. Start emission by pressing the Unlock button on the 
sending unit. Stop emission by pressing the Lock button. Multiple Blizzard 
1200 may be controlled using only one sending unit. 
 

3.3 DMX Mode 
 

In DMX mode, you can control the fixture with a DMX controller. 

DMX Protocol: 
Std. 

DMX 

Function 

CH1 0-255  Output 

0-100% 

 

                                                                    7/11               

©

PHANTOS

®

 

  Distributed in Australia by PHANTOS  www.phantos.com.au   

 

4. TROUBLE SHOOTING 

 
1. Unit does not respond to DMX: 
Check that the DMX cables are connected properly and are wired 
correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’). 
It does matter which way the inputs and outputs are connected. 
 
2. Low output, mechanical noise or no output at all: 
Unplug immediately and check fluid level, the external fuse, remote 
connection, and power from the wall. If all of the above appears to be 
O.K., plug the unit in again. If machine does not function after 30 
seconds, discontinue operation or permanent damage to the unit may 
result. Return the machine to your dealer. Always drain tank before 
mailing or transporting this unit. 
 

 

Disconnect from mains before servicing. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 