B
08.06
51
CHAPTER
PAGE
ISSUE
ELECTRIC SYSTEM TROUBLESHOOTING
ENGLISH
SECTION 2
Signal System
SECTION 2
B
- TROUBLESHOOTING
3
Radiator fluid temperature indicator
function
This information is provided by the bottom section
of the bar graph, accompanied by the radiator fluid
icon. A connection failure of the resistive probe to
the instrument board will be signalled by the LED
flashing.
The bar graph is updated every 0.5 seconds and
controlled in accordance to the following table:
temp [°C]
< 30
30 ÷ 40
40 ÷ 50
50 ÷ 60
60 ÷ 70
70 ÷ 80
80 ÷ 90
90 ÷110
> 110
8+LED
Tolerance: ±10%
Resistance [ ]
2449
1661
1148
810
582
426
315
240
N. of
segments
1
2
3
4
5
6
7
8
The alarm LED will only go off when temperature
drops below 110°C. All values refer to the
temperature sensor used (Yamaha code
5601991000).
Wtemp function