B
38
08.06
CHAPTER
PAGE
ISSUE
ELECTRIC SYSTEM TROUBLESHOOTING
ENGLISH
SECTION 2
Signal System
SECTION 2
B
- TROUBLESHOOTING
5.
Check voltage delivered to right hand and
left hand lamp sockets
-
Connect Tester (20V DC) to connector of lamp
coupling
(A) Left hand turn indicator
Terminal (+)
Purple cable (1)
Terminal (-)
Chassis grounding cable
(B) Right hand turn indicator
Terminal (+)
Green cable (2)
Terminal (-)
Chassis grounding cable
1
2
-
Turn key “ON”
-
(A) operate the switch, to activate the left hand
turn indicators
-
(B) operate the switch, to activate the right hand
turn indicators
-
Power measured in both cases must be 12.5V
COMPLIANT
Circuit is in working order
NOT COMPLIANT
Cable interrupted between turn indicators and
connector of lamp coupling. Resume
connection.
See “Circuit Diagram”