76
10/07
- Check the rotor axial clearance using
a rectified bar as reference plane, as
shown in the figure.
Characteristic
Limit values admitted:
0.1 mm
Refitting
- Make sure the gasket is in the correct
position.
N.B.
THE TOOTH OF THE GASKET MUST BE IN
ITS SEAT.
- Lubricate the internal rotors.
- Check there are no signs of scoring or
wear on the oil pump cover.
- If non-conforming values or signs of
wear are found, replace the pump.
- Fit the pump cover in the position that
permits the crankcase fixing screws to
be aligned.
- Tighten the two fastening screws to
the prescribed torque.
Locking torques (N*m)
Oil pump cover screws
0.7 ÷ 0.9
- Insert the oil pump with gear
- Insert the 2 retaining screws through the slots on the gear and tighten to the
prescribed torque.
N.B.
THE ASSEMBLY POSITION OF THE PUMP IS FIXED BY INSTALLATION OF THE SCREWS.