INSTALLATION DATA
ELECTRICITY CONNECTION
•
The boiler works with 230 v. 50 Hz. alternative current.
•
Please make sure that the fuse supplied along the boiler is installed maximum
10 cm . away from the boiler.
•
An electricity cable of 3x1,5 mm² must be laid out by an authorised electrician.
•
The boiler works with ground line.. Both for your and the boilers safety, please
make sure that the grounding is done properly.
•
Please make the phase, neutral and ground line connection as shown on the
scheme.
IMPORTANT
•
The boiler does not operate when the connection is done improperly.
•
The cable of the boiler must be connected as shown:
Brown:
Connect this to phase cable.
Blue:
Connect this to neutral cable.
Yellow-Green:
Connect this to ground cable.
Boiler
System
OPENING THE BOX
1.
Put the box on the floor as arrows showing down and open the box by cutting
packing belts.
2.
Open the covers by folding on 4 sides as shown in figure.
3.
Turn down the box as shown in figure and pull box to up and remove it from
the box.