FULL AUTOMATIC PELLET-FUELED BOILER 

OPERATING AND USING MANUAL

25-40-60 MKP

   kk 10

rev.no:0

2

05.04.19

 

TS EN ISO 9001:2015 

Please Keep

Please Read

Содержание 25 MKP

Страница 1: ...FULL AUTOMATIC PELLET FUELED BOILER OPERATING AND USING MANUAL 25 40 60 MKP kk 10 rev no 02 05 04 19 TS EN ISO 9001 2015 Please Keep Please Read ...

Страница 2: ...RAM 4 3 VENTILATION 4 4 CHIMNEY 4 5 CHIMNEY CONNECTION SCHEMA 5 TECNICAL SPECIFICATION TABLE 6 CONTROL PANEL 6 1 ERROR CODES 6 2 LCD SCREEN SYMBOLS 7 STARTING UP AND USAGE 7 1 FIRST BURNING 7 2 WARNINGS ABOUT PELLET 7 3 USAGE PRECAUTIONS 8 CLEANING AND MAINTENANCE 9 OFFERS FOR ECONOMICAL USAGE 10 ELECTRICAL SCHEMA 11 FAILURES AND SOLUTIONS 12 SHIPPING AND HANDLING Page 10 Page 11 Page 12 Page 12 P...

Страница 3: ...ments that are closely followed Our company has acquired advanced technology and superior quality as a guide and continues to way in line with these principles This handbook is a helpful guide to the user for installing operating and maintaining the boiler For failures and maintenance please contact our authorized service Our after sales service network is always at your service with plenty of spa...

Страница 4: ...ing out of the combustion chamber Do not remove the outer cover sheets of the boiler do not open the protective covers Risk of burns as a result of a contact to hot surfaces and risk of electric shock resulting from contact with electrical components Do not disconnect the boiler from the place where it was installed Do not interrupt its connections During the disconnecting process there is a risk ...

Страница 5: ...o install boilers in enclosed spaces where people live Do not operate boilers without water Never make a cold water supply to a hot boiler If the boiler temperature has risen above 90 C for any reason do not cool the boiler and do not supply cold water to increase the water level until the boiler temperature decrease below 40 C Water at the installation should not be discharged except for repair a...

Страница 6: ...special fuel loading settings Ability to monitor loading and stand by times from the electronic control panel by adjusting from the digital display High durability combustion chamber made of 310 CrNi Steel Extremely quiet operation with cycle control and exhaust fan ensures maximum efficiency with quiet speed control Easy cleaning of the smoke pipes with the manual cleaning mechanism Ashes are pou...

Страница 7: ...3 APPEARANCE OF THE BOILER AND EXTERNAL DIMENSIONS 7 ...

Страница 8: ...ar Safety Valve 5 Expansion Tank 6 Reducer Motor 7 Bunker 8 Fuel Loading Cover 9 Fuel Level Sensor 10 Chimney Outlet 11 Chimney Temperature Sensor 12 Cleaning Mechanism Handle 13 Outlet 1 14 Fan 15 Filling Pipe Temprature Sensor 16 Ignation Resistance 17 Inlet 1 18 Filling 1 2 ...

Страница 9: ...3 2 MINIMUM SPACES FOR INSTALLATION This 500 mm dimension is only neccessary for 40 MKP and 60 MKP boilers 9 ...

Страница 10: ...irst starting boiler connecting to the installation The best way is to give water from one side of the pipes and drain it from the other side The circulation pump should be mounted on the return pipe of the boiler water There should be adequate space left for service intervention device control and fuel loading while device is mounting Valve connection should be made on the boiler water return lin...

Страница 11: ...nstallation at minimum An infinite power source may be used for electricty cut as an extra security measure Install a 3 bar safety valve on the boiler for protection against over pressure The diameter of the safety valve should be min 1 It is recommended to mount circulation pump on return line for protecting it from overheating stream All connections and valve positions must be checked after the ...

Страница 12: ...4 2 BOILER INSTALLATION MOUNTING DIAGRAM 12 ...

Страница 13: ...60 cm and longer than 2 meters and pipe must be connected to the chimney with minimum 10 degree of angle We suggest not to use enamel stove pipes bause they cause tars in chimney connection pipe or chimney system In case of an elbow use in chimney connection the elbows must have round and wide angle Quantity of an elbow must be maximum 2 pieces Chimney connection must be installed to allow demount...

Страница 14: ...chimney must pass from outside the isolation must be done properly The chimney must be frequently cleaned in order to avoid forming tar and soot and clogs that would prevent chimney draught There shouldn t be foreign objects cement or surface fragments inside the chimney as these would cause narrowing in sections of chimney and result in decrease on chimney draught ...

Страница 15: ...orking Pressure bar 3 3 3 Test Pressure bar 4 5 4 5 4 5 Circulation Inlet Outlet 3 4 1 1 Security Inlet 1 2 1 2 1 2 Boiler Setting Range Min Max C 35 90 35 90 35 90 Boiler Water Volume lt 46 106 146 Fuel Tank Volume kg 210 226 226 Closed Expansion lt 8 10 10 Voltage V Hz 230 50 230 50 230 50 Power Max W 900 900 900 Electricity Isolation Degree IP 14A 14A 14A ...

Страница 16: ...equate press the button once to change the fuel waiting values and adjust with the increase and decrease buttons Increasing ButtonEnter the menu which is desired to be changed and use this button to increase the value Which situation is to be used first must be pressed on that button Reducing Button Enter the menu which is desired to be changed and use this button to reduce the value Which situati...

Страница 17: ... LCD SREEN SYMBOLS Fan is Activated Reducer Motor is Activated Circulation Pump is Activated Error Symbol Burning Occured Symbol Automatic Ignition Resistance is Activated Heating Circuit is Working Fan Level ...

Страница 18: ...ss will be done by boiler itself because the boiler is fully automatic During the ignition operation the temperature and auto setting writings will be replace and flash on the LCD When the combustion occurs the burning symbol appears on the screen and the boiler continues to run automatically at the factory settings Factory settings are recommended as user settings and are given in the table below...

Страница 19: ...to the radiators The boiler water temperature continuously decreases when the fuel is exhausted and the circulation pump is deactivated when it reaches 30 C When the boiler water temperature drops to 25 C all functions stop The fan is automatically switched off when the boiler water temperature reaches at the set thermostat limit The fan starts to work again when the boiler water temperature falls...

Страница 20: ... the fan If any deterioration is observed in the combustion combustion chamber can be cleaned by inserting a hard material with appropriate diameter in its holes Cut off all electricity connections before starting maintenance of the boiler Ventilate the air in tha place while cleaning the boiler Before the winter season maintain the electrical chimney and plumbing connections of the boiler Check b...

Страница 21: ...10 ELECTRIC SCHEMA 21 ...

Страница 22: ...holes may be clogged Open the blockage by inserting a hard object with an appropriate diameter into the air holes Fuel may be wet Make sure you use fuel for the specifications indicated in the user manual Improper fuel usage Be sure that you use fuel that has specifications stated in operating manual Combustion chamber resistance outlet front may be clogged Clean the combustion chamber resistance ...

Страница 23: ...Hot Boiler Limit Thermostat Boiler water may be missing Stop burning and do not add water to boiler until it cools down Fill1 5 bar water when it drops under 50 C The circulation pump may be jammed Remove the back screw of the circulation pump and turn the rotor manually with screwdriver Radiator valves or installation valves may be closed Open the valves Vent the trapped air from the system There...

Страница 24: ...g being under the boiler Boiler must be carried with its accessories installed on it B CARRYING BOILER ON VEHICLE When the boiler is carrying with vehicle it must be tied to vehicle strictly supporting stuff which would prevent slipping should be put around Boiler should not be carried along with fragile smashable and living beings Top of the vehicle must be covered with canvas after placing boile...

Страница 25: ...Seller Maktek Kazan Radyator Klima San A Ş 10013 Sk No 14 A O S B Çiğli İZMİR Tel 0 232 328 21 06 07 08 Faks 0 232 328 04 86 www maktek com tr info maktek com tr ...