4.3 VENTILATION
The area where the boiler is installed, must always be suppplied with fresh
air by opening a window or a duct. Fresh air is required in order to burn the
fuel safely and efficiently. Otherwise once the burning starts, the oxygen
level will drop and the burning will detoriate. Detoriation of burning will
cause
the
burning efficiency
to decrease, accumulation of soot in the
chimney and
will require frequent cleaning.
4.4 CHIMNEY
•
The chimney that will be connected to the boiler must be
seperate
.
The
chimney
must
be connected to provide a
dequate
draught. A boiler
without chimney
connection should
not be operated.
•
Chimney connection pipe and pipe systematic should be installed and
checked
by
authorized people only. We remind you that the biggest
factor in boiler efficiency
is
chimney design and draught.
•
Proper chimney connection pipe should not
be
smaller than the
boiler's
chimney
diameter,
horizontal length must not be shorter than
60 cm
and longer than 2 meters
and pipe
must be connected to the
chimney
with minimum 10 degree of angle.
•
We suggest not to use enamel stove pipes bause they cause tars in
chimney
connection pipe or chimney system.
•
In case of an elbow use in chimney connection, the elbows must have
round
and wide
angle. Quantity of an elbow must be maximum 2
pieces.
•
Chimney connection must be installed to allow demounting from the
boiler and
avoid
gas leaking.
•
Chimney connection pipe must not be extended to the outside and
must be
connected to a chimney.
•
Chimney connection pipe's contact with flammable material must be
avoided.
•
Chimney connection pipe shouldn't be pushed inside the chimney.
•
The direction of the chimney should not be changed. If there is a
turnaround
need,it must be positioned by 60
°C.
•
The chimney must be leak proof and air transperancy from inside and
outside
must be avoided.
•
Do not connect more than one boiler and another device to same
chimney. This
would decrease chimney draught and boiler efficiency.
•
There should be no contact between the chimneys which are placed
side by
side.
•
There should be no sectional narrowing in any part of the chimney.