background image

 

14 

                                                             

  

 

 
 
6.  BOILER WITH STOCKER CONTROL PANEL

 

 

 

( Fuel Waiting Period Setting Button )

 

(

Fuel Feeding Period Setting Button)

 

Fan Button )

 

Termostat Setting Button)

 

(

 

Fan Led )

 

 (Pump Led)

 

 
(

 Fuel Finshed Led)

 

(

 Fuel Squeezed Led)

 

( Up

 Burron)

 

 (

Down Button)

 

7 part Led Indicator )

 

 

 

(

 Reductor Button ) 

 

(

 Fan Button) 

(Fuel Feeding Button)

 

 

(Alarm Button) 

 (On/ Off Button)

 

 
 

 

Fuel Feed Button

 

 Feeds  the fuel  manually  when fuel  feed button is pushed

 

Reductor Button 

 

 Reductor becomes  ON or OFF when Reductor button is pushed.

 

Fan Button 

 

Fan becomes  ON or OFF when Fan button is pushed

 

On/ Off Button

 

System becomes ON or  OFF  ( Button should be pushed 2 seconds for 
both position)

 

Alarm Button

 

Alarm stops 

 

Increasing Button

 

Increases the value of the set function

 

Decreasing Button

 

Decreases the value of the set function

 

Lcd Screen

 

 Shows the temperature   in normal  conditions. In setting condition, setting 
value is shown on screen.

 

Fuel waiting period 

setting button  

 

Sets the waiting period after fuel loading (04-255 sec) 

 

 Fuel feeding  period 

setting button 

 

Sets fuel  loading  period. (04-60 sec)

 

Fan Setting Button

 

Sets speed level of fan ( From 1 to  5 )

 

Thermostat Setting Button

 

Adjust the intended temperature ( from 

35 °C' to to  90 °C)

 

  Fan led

 

Shows fan  activation

 

Pump led

 

Shows pump  activation

 

Reductor led

 

Shows reductor  activation. 

 

No Fuel  led

 

Shows lack of fuel

 

Fuel Congestion Led

 

Shows reductor is congested

 

Failure Codes

 

 

* ( H1 )  No Fuel 
* ( H2 )  Heating sensor is not connected or broken 
*( H3 )  Temperature of the boiler water is very high 
*( H4 )   Fuel is congested  in reductor

 

ATTENTION !!!

 Fuel loading and feeding value is in Table 1.  Loading and feeding settings belongs to the fuel only  

It is necessary to do new settings when the fuel type is changed

 

SAFETY TERMOSTAT 

  Safety termostat is placed behind the control panel and is active during a possible 

breakdown of boiler water setting thermostat  to prevent the increase of boiler water temperature. Hence, ensures an 
extra safety and protects the boiler. Recommended to be set at  80 °C.

 

IMPORTANT!!!

 

Current boiler water temprature is shown on digital screen when adjustment settings is not in use 

 

Содержание 25 MKK-S

Страница 1: ...1...

Страница 2: ...TION AND WATER FLOOD 9 BOILER INSTALLATION SCHEMA 10 4 2 AIR CONNECTION 11 4 3 CHIMNEY 11 CHIMNEY CONNECTION SCHEMA 12 5 TECHICAL FEATURES 13 6 CONTROL PANEL 14 7 FIRST OPEATION AND USE 15 7 1 FIRST B...

Страница 3: ...y and World market Our company which has acquired advanced technology and superior quality stands on in accordance with these principles This handbook is a helpful guide during operation and maintenan...

Страница 4: ...strictly forbidden Please do not operate the boiler without water Do not feed cold water to hot boiler If for any reason the boiler temprature is over 90 degrees do not attempt to feed cold water to t...

Страница 5: ...g and waiting time on the electronic control panel Detoriations as a result of burning are minimised thanks to cast iron burning bunker Fan with quiet running cycle period and clap ensures maximum eff...

Страница 6: ...6 3 SECTIONS OF THE BOILER See techic table for dimensions stated with letters 5 6...

Страница 7: ...r must be connected to a good drawing chimney and minimum number of elbows should be used between chimney and boiler Boiler must be placed at a location with enough air intake for an efificient burnin...

Страница 8: ...om one end of the pipes and to drain off at the other side Circulation pump must be installed on boiler water return pipe During installation there must be enough working space left for technical serv...

Страница 9: ...n of hot water must be provided by natural circulation The diameter of the pipe to be used at by pass line should be the same diameter size with the pipe used in installation at minimum As an extra se...

Страница 10: ...10 BOILER INSTALLATION SCHEMA...

Страница 11: ...ertical length must not be shorter than 60 cm and longer than 2 meters and pipe must be connected to the chimney with minimum 10 degree of angle We suggest not to use enamel stove pipes as it creates...

Страница 12: ...the building if the chimney must pass from outside the isolation must be done properly The chimney must be frequently cleaned in order to avoid tar and soot and clogs Please avoid foreign objects cem...

Страница 13: ...13 5 TECHNICAL SPECIFICATION...

Страница 14: ...r fuel loading 04 255 sec Fuel feeding period setting button Sets fuel loading period 04 60 sec Fan Setting Button Sets speed level of fan From 1 to 5 Thermostat Setting Button Adjust the intended tem...

Страница 15: ...iler lids must be closed and fan must be runned in low speed until the coal is completely combusted If fan blows too much air big slinders occurr because of the cooling effect of burning tank Make the...

Страница 16: ...ses 5 C below set degree Running and stopping of circulation pump and fan can be monitored from flashing leds on digital indicator on control panel Circulation pump will run automatically for 3 second...

Страница 17: ...nclogged Air holes must be cleaned up by turning on the fan for 15 minutes Electricity connection must be cut off before the maintainance Please ventilate the area before cleaning the boiler Electrici...

Страница 18: ...18 10 ELECTRICITY SCHEMA...

Страница 19: ...e comes from chimney connections Air holes which are inside the boiler can be blocked Clean up holes and smoke pipes regularly Boiler Chimney connections can be loosen Check the boiler chimney exit an...

Страница 20: ...use of the supporting ring When the boiler is lifted up with crane there shouldn t any living being under the boiler Boiler must be carried with its accessories installed on it B CARRYING BOILER ON VE...

Отзывы: