Maktec MT605 Скачать руководство пользователя страница 4

[3] DISASSEMBLY/ASSEMBLY

[3]-2. Spindle and Helical Gear

DISASSEMBLING

ASSEMBLING

(3) Remove Helical gear 35 and Ball bearing 6902ZZ (

Fig. 5)

.

Note: 1. Use new Ring spring 13 after mounting Ball bearing 6902ZZ if it is deformed.

          2. Make sure to fix Helical gear 35 at correct direction as in 

Fig. 6

.

Do the reverse step of Disassembling (

Fig. 5

,  

Fig. 4)

.

3. Set Helical gear 35 to a supporting jig

    and press Spindle with Arbor press

    to remove Spindle from Helical gear.

4. Remove Ring spring 13 

    from Spindle.

5. Now, Ball bearing 6902ZZ

    is removed from Spindle.

Fig. 5

Helical gear 35

Ring spring 13

Note: Make sure to use new Ring spring 13

         when the removed one is deformed.

Ball bearing 6902ZZ

Spindle

Fig. 6

Locate the Grooved side to the small Ball bearing 606ZZ side

and mount Helical gear 35 to Spindle.

Ball bearing 606ZZ

Groove on Helical gear 35

R

epair

 

P  

4

9

Содержание MT605

Страница 1: ...chuck model with variable speed control and reverse function MT607 Keyless chuck model with variable speed control and reverse function Model MT607 is available with plastic carrying case as model num...

Страница 2: ...ed by Makita to the portions pointed with triangles to protect parts and product from unusual abrasion DISASSEMBLING Fig 1 Item No Description Lubricant Amount 4 0 g Portion to lubricate Makita grease...

Страница 3: ...2 Fig 3 2 Remove Spindle and Helical gear 35 Fig 4 Do the reverse step of Disassembling Fig 4 Fig 3 Set up the Repairing tool Insert 1R231 into Bit adapter and turn 1R233 counter clockwise to remove...

Страница 4: ...ing Fig 5 Fig 4 3 Set Helical gear 35 to a supporting jig and press Spindle with Arbor press to remove Spindle from Helical gear 4 Remove Ring spring 13 from Spindle 5 Now Ball bearing 6902ZZ is remov...

Страница 5: ...L at the Bearing box for Ball bearing 627ZZ of Armature s commutator side Fig 8 Fig 7 Leaf spring Housing L 1 Separate Motor section Field and Armature from Housing L Then remove Leaf spring 2 Pull o...

Страница 6: ...ssion Housing R side Choke coil Brush Holder Orange Purple Color index of lead wires sheath Black Red Brush Holder Brown lead wire is used for some countries instead of black Blue lead wire is used fo...

Страница 7: ...connect them to Switch Fix the Field lead wire red with the Lead wire holder on Switch Fix the Lead wires with Lead wire holder Do not route the Field lead wire Purple over Brush holder or rib for Sw...

Страница 8: ...side Choke Coil Brush holder Orange Purple Color index of lead wires sheath Black Switch Field Housing L side Housing R side Brush Holder This Lead wire is brown for some countries in stead of black T...

Страница 9: ...Choke Coil Fix the Lead wires with Lead wire holder Pass the Field lead wires under Brush holder Fix the Lead wires with Lead wire holder Noise Suppressor If the Equipment of Radio Interference suppr...