background image

 

22 

Sensitivity consists of 3 steps:  

Max:

  The  sensitivity  step  where  the  depth  of  the  device  is  maximum. 

When  the  device  is  used  with  this  step,  it  can  easily  detect  even  small 
objects  from  a  deep  distance.  As  this  step  provides  the  device  with 
excessive sensitivity and power; the device will be increasingly affected 
from  the  earth  and  will  become  more  difficult  to  use.  Therefore,  the 
ground  setting  should  be  made  in  the  best  manner  possible. When  the 
sensitivity setting is set to “Max”, the ground setting must be done again. 

Between Min2 - Max: 

It has a high perception capacity. It is preferred for 

types of ground, for which “Max” step cannot be used. It has perception 
depth  that  is  lower  than  “Max”  but  it  is  less  affected  by  the  structure  of 
soil  as  compared  to  the  "Max”  step.  And  when  it  is  turned  from  Min2 
towards Max level, sensitivity level will continue to rise. 

Min  1: 

The  lowest  level  of  sensitivity.  At  this  level,  the  device  is  least 

affected from the soil. Soil setting may be made easily but at this level, 
the device may have difficulties in detecting small objects. 

This should 

be used to detect the large metals or large holes. 

 

 

WHAT IS GROUND SETTING AND HOW IT IS DONE? 

 

In  our  country  land  formation  and  soil  composition  vary  in  relation  to 
regions.  In  some  regions  the  composition  may  vary  frequently  (Sand, 
lime, red earth with dense mineral content, rocky formation, etc.). 
These  variations  in  soil  composition  mislead  the  detector  and  cause 
perception  as  metal  or  void.  Therefore  first  we  have  to  launch  the  soil 
characteristics  of  the  region  to  the  detector’s  system.  Launching  these 
data will block all misleading effects that may come up from the ground; 
these will be perceived as misleading signals from the ground, and thus 
eliminated.  
Ground  setting  is  one  of  the  most  important  provisions  of  exploration. 
Therefore the operator should be a keen observer and should be able to 
detect  variations  in  the  ground.  He  has  to  observe  soil  compositions 
continuously  to  be  able  to  make  ground  adjustment  again  in  case 
misleading signals the device will perceive results from variations in soil 
composition. 
Ground setting is made for the device to recognize the soil and not to be 
affected  by  it.  Thus  the  device  is  not  affected  from  metal  or  void 
reflections of varying soil compositions. If ground setting is not properly 

Содержание JEOTECH

Страница 1: ...1...

Страница 2: ...CONTENTS Jeotech Accessories and Components 5 Jeotech System Unit and Joystick 8 Assembly and Charging the Battery 11 Jeotech Using Phases 17 Ground Setting 21 Ground Setting Phases 22 Explore Mode 2...

Страница 3: ...3 WARNINGS CAUTION PLEASE DO NOT START ASSEMBLING OR USING BEFORE READING THE WARNINGS SECTION...

Страница 4: ...3 DO NOT USE ANY OTHER DETECTOR OR A DEVICE THAT EMIT MAGNETIC WAVES WITHIN 10 m PROXIMITY OF THE DEVICE 4 PREVENT THE DEVICE FROM ABRUPT MOVEMENTS AND POSSIBLE SHOCK 5 DO NOT EXPOSE THE DETECTOR HEAD...

Страница 5: ...5...

Страница 6: ...6 JEOTECH ACCESSORIES AND COMPONENTS...

Страница 7: ...where the detector sockets earphone socket and battery socket are located and where measurement results are evaluated and displayed on the LED monitor on joystick 2 210x315 Detector Head It is the an...

Страница 8: ...utput DC 9 12 V 400 mA Charge duration 10 hours 5 Carrying Case It is a case used for transport and storing of the System Unit the 210x315 Detector Head and accessories 6 Earphone It is the piece that...

Страница 9: ...9 JEOTECH SYSTEM UNIT AND JOYSTICK...

Страница 10: ...is used for turning on the device 2 GROUND SWITCH The switch that is used for ground setting 3 SENSITIVITY The switch that is used for adjusting the sensivity level 4 SOUND AND LIGHT ADJUSTING SWITCH...

Страница 11: ...t is a ferrous metal 4 POWER LIGHT The light shows that the device is on 5 NON FERROUS LIGHT The light shows that the target is a non ferrous metal 6 METAL and MINERAL If there is a metal effect on th...

Страница 12: ...12 JEOTECH ASSEMBLY AND CHARGING THE BATTERIES...

Страница 13: ...the sleeve The detector head is dismounted from the extension tube when packing in the carrying case Dismantling is carried out as the reverse of the process described above CAUTION Do not take apart...

Страница 14: ...Electronic system box The 5 pin plugs shown in the above figure are connected to socket on the system box EARPHONE CONNECTION Enables signal sound to be switched from external loudspeaker to the earp...

Страница 15: ...fective battery is connected to the charger green light on the charger blinks 5 times a short beep tone is heard and the green light turns into red blinks repeatedly and frequent beeps are heard In su...

Страница 16: ...nt When the setup is completed a short beep sound is heard and charging starts ATTENTION During the setting period do not disconnect the battery from the charger During the charging process the blinki...

Страница 17: ...17...

Страница 18: ...18 JEOTECH USING PHASES...

Страница 19: ...out to be dead If three lights are on and off periodically the device power is not enough to operate the device If there is no light on the battery is flat When the battery charge is weak the device s...

Страница 20: ...in and Max after the device is turned on and the light level is set NOTE When battery is flat all three BATTERY lights flash and a sound alarm is generated NOTE When search cap breaks down or when the...

Страница 21: ...ce unable to detect the target Reset takes place after the search cap is taken to a side off the target Don t forget to reset after every action you take Exercise due care not to reset on the target U...

Страница 22: ...objects This should be used to detect the large metals or large holes WHAT IS GROUND SETTING AND HOW IT IS DONE In our country land formation and soil composition vary in relation to regions In some r...

Страница 23: ...eliminate ground effect on the device Steps for the Ground Setting 1 The device is turned on 2 The Ground Setting should be made at a spot where one is sure that there is no metal and Cavity If the gr...

Страница 24: ...ere is a ground effect on the device the METAL and MINERAL or CAVITY and MINERAL lights of the device will be on 6 In case of a warning for METAL and MINERAL a Raise the search cap of the device by 40...

Страница 25: ...alerts e In such a case raise the search cap to a distance of 40 cm Press the ground button a few times in direction and reset Take the search cap close to the ground by the same distances again If t...

Страница 26: ...rform a search on such ground d If the ground effect continues the device will continue to keep the Cavity and Mineral lights on and to generate a sound alert e In such a case raise the search cap to...

Страница 27: ...h with a single light on the Metal and Mineral or Cavity and Mineral side NOTE As the sensitivity levels are reduced there is a decline in sensitivity in detecting metals NOTE The search must be condu...

Страница 28: ...28 SEARCH WITH A DEVICE WITH GROUND SETTING...

Страница 29: ...device detects Cavity the CAVITY AND MINERAL lights on the screen will be on depending on the signal strength and a sound alert will be generated If our target is metal or Cavity then the device gener...

Страница 30: ...to the side away from the target when you receive a metal signal and move over the target again after pressing the SCAN button in this case if the metal is a valuable metal NONFERROUS light will be on...

Страница 31: ...31...

Страница 32: ...32...

Отзывы: