25
c. If the effect on device is eliminated as a result of such procedures,
none of the “Metal and Mineral” lights will be on (“Cavity and Mineral”
lights shouldn't be on, either.) This will mean that the device is suitable to
make a search on that ground.
d. If the ground effect continues, the device will continue to turn on
“Metal and Mineral” lights and to generate sound alerts.
e. In such a case, raise the search cap to a distance of 40 cm.
Press
the ground button a few times in “+” direction
and reset. Take the
search cap close to the ground by the same distances again. If the lights
are on and the sound alert continues (and the number of lights on will be
reduced after every action) these procedures should be continued until
the effect is lost.
7.
In case of an alert for “CAVITY and
MINERAL”:
a. Raise the search head to 40 cm above the ground and hold it parallel
to the ground
. Press the button in “ -- “ direction
. Then reset
immediately.
RESET