MAKOI Bio100 Скачать руководство пользователя страница 9

 

 

 

Misprints and printing errors reserved 

 

If the float is floating, the system is on stand-by. If the 
float is in the lowest position, the process will commence 
(drum starts rotating and the rinse pump will rinse the 
cloth). This will last for 14 seconds. 

If

 the float remains in the lowest position (and the pond 

pump is on) there will be too little water supply from the 
pond. The drum will rinse for 30 seconds (standard value) 
and then switch to dry-running mode.  
This is to protect 
your pond pump. 
Once the float goes 
back to normal 
position (it will float 
again because 
sufficient water flew 
into the filter) the 
pump will activate 
after 5 minutes 
(standard value). 

7.2.6 Control electronics 

The control electronics has protection class IP54. 

Electrical installations must always comply with the 
national and international requirements/guidelines.  

Only open the casing of the electronics to 
connect the float and magnet contact or to 
set the parameters. When connecting the 
float and magnet contact, disconnect the 
device from the power supply before 

connecting it! Changing the parameters is done at own risk 
in case the power supply is connected. Take care of 
electrical hazard when opening.  

The control cabinet must be connected 
to an approved, earthed socket. The 
electronics must be installed vertically. 
The electronics may not be assembled 
unprotected during rain. Per connected 
side, a maximum of 660 W of auxiliary 

equipment may be connected.  

Functions of the green button: 

Press 1 time:    

 

Filter will start to rinse. 

Quickly press 2 times:    

Filter and duct will rinse* 

Quickly press 4 times:   

Filter into emergency mode  

                                             Periodic rinsing. 
                                             If float is defective. 

Press for 3 seconds: 

 

Rinse counter reset. 

Press for 8 seconds: 

 

Text message module 
sends (test) alarm. 

While pressing: 

 

Total number of rinses       
visible on screen. 

 

Connection 1-2:

 Float switch 

Connection 3-4:

 Lid of magnet contact. This is a 

protection for opening the lid. If the lid is opened, the 
drum filter will not rinse. 

Display on white:

 

Filter is operational 

Display red:

 

Lid is open and drum filter will not rinse! 
Pond pump will keep running. This is only when the 

Float is 

in ‘

rinse

’ 

position, pond pump is on. 

Drum is rotating and rinse pump rinses the 
cloth. If the float remains in this position for 
30 seconds, the electronics will switch to 
DRY-RUNNING MODE. 

Motor 

Pond pump 

Rinse pump 

Содержание Bio100

Страница 1: ...1 Misprints and printing errors reserved INSTALLATION AND USER GUIDE FOR MAKOI DRUM FILTERS AND BIODRUMS Scan the QR code for even more information ...

Страница 2: ... 5 7 Commissioning of the filter 6 7 1 Positioning the filter 6 7 2 Connecting gravity 6 7 2 1 Setting of sensor float 7 7 2 3 Connecting rinse pump 7 7 2 4 Connecting motor drum filter 8 7 2 5 Coil frequency 8 7 2 6 Control electronics 9 7 2 7 Control electronics for Drum 100 and Bio drum 200 with flushing channel connection 10 7 3 Connecting pump fed system 10 7 3 1 Installation of float 10 7 3 ...

Страница 3: ...ith regard to the usage and the suitability for an application will be accepted only if they fall within the Ma koi specifications specified in writing as for instance stated in this manual Any other verbal agreements for instance during preparatory discussions advertisement etc in relation to the product are valid only in case what was pledged is an integral part of a written agreement Only the t...

Страница 4: ...bject to modification The specifications of the filter offer will prevail and are guaranteed 3 GENERAL 3 1 Description of the drum filter The Bio drum and or the drum filter consists of a drum sieve that is driven by an electro motor Additionally control electronics and a rinse pump are included The drum filter serves to filter and discharge floating particles dirt particles and algal remains Rega...

Страница 5: ...h a maximum residual current of 30 mA DIN VDE 0100T739 Use the device only when connected to a correctly installed socket Keep the plug and the wiring dry Ensure that the cables are protected to prevent damage and consequential short circuit THE ELECTRICAL WIRING AND OR PLUGS MAY NOT BE CUT THROUGH DOING THIS WILL CAUSE THE MANUFACTURER S WARRANTY TO EXPIRE IMMEDIATELY Only use cables installation...

Страница 6: ...cs contains switching components and must be placed in an interference free room Certain pumps or UV units may adversely affect the functioning of the electronics In case of frost the filter must be protected against freezing If the filter is being activated outdoors all pipes must be empty If the filter remains operative the pipes for the rinse water must be protected against freezing Damage as a...

Страница 7: ...ged This is indicated on the display Siemens Logo in the Electronics Cabinet 7 2 1 Setting for sensor float Upon delivery the sensor has already been installed for use as gravity and in such a way that it will function properly in most situations Still you will need to check on proper functioning after installation and adjust the float in the best way possible If the float is in lowest position 4 ...

Страница 8: ... frequency Make sure that the coil frequency is not too high If the drum is installed in an existing system the coil frequency will be high over the first days weeks because the pond is being cleaned In case of warm weather the coil frequency will be higher more feed and more algae growth than in case of colder weather Other causes of a too high coil frequency are a pond pump that is too large too...

Страница 9: ...ing the parameters is done at own risk in case the power supply is connected Take care of electrical hazard when opening The control cabinet must be connected to an approved earthed socket The electronics must be installed vertically The electronics may not be assembled unprotected during rain Per connected side a maximum of 660 W of auxiliary equipment may be connected Functions of the green butt...

Страница 10: ...float upside down for the drum section at the inlet 1st chamber Please note The float must be installed in reverse because here the circuit is to work reversely And the upper blue caps must be removed If the water rises for the drum filter it becomes polluted and the rinse cycle must be activated If in the reversed situation the float goes up and stays up the system should deactivate after 30 seco...

Страница 11: ...ance and cleaning The filters are low maintenance However maintenance and inspection tasks below are required for proper functioning Check the correct functioning of the float every month Perform a manual rinse every month and check whether the nozzles perform good spraying A nozzle may get clogged or calcified Also the rinse pump may perform less pressure Clean the nozzles if necessary Clean the ...