background image

8

Care and advice on operation

Makita SK103P

en

GB

F

I

E
P

NL

DK

S
N

FIN

J

CN

ROK

PL

HR

H

RUS

CZ

GR

LT

LV

EST

SLO

SK

M

TR

Checking the accuracy of the vertical 
plumbing of the SK103P:

Place the Lock switch 

3

 in the "Unlocked" (

position. 

Checking the upper plumbing point:

Checking the lower plumbing point:

Set up the laser on its tripod or wall mount bracket near point 
A1 at a minimum distance of 1.5 m from point B1. The hori-
zontal laser is aligned in direction 1. Mark the laser dots A1 
and B1 with a pin. 
Rotate the instrument by 180° so that it points in the opposite 
direction 2 to direction 1. Adjust the instrument so that the 

laser beam hits point A1 exactly. If point B2 is no further than 
2 mm away from point B1, then the SK103P is within toler-
ance.

Should your SK103P be outside of the specified 

tolerance, please contact an authorised dealership of 
Makita.

Display notices

Falling below or exceeding the permissible temperature 
range: 

The laser switches off and all symbols flash.

Outside of the self-levelling range:

The laser beam is flashing.

Pendulum locked:

The laser beam is not levelled and the Lock symbol 

4

 lights 

up.

Care and advice on operation

Do not immerse the instrument in water. Wipe off dirt with a 
damp soft cloth. Do not use aggressive cleaning agents or 
solvents. Treat the instrument with the same care that you 
would apply to binoculars or a camera.
Dropping or violent shaking of the instrument may damage 
it. Check the instrument for any damage before using it. 
Check the levelling accuracy of the instrument regularly.

Transport

To safely transport the instrument, set the Lock switch 

3

 to 

"Locked" (

). 

1

B1

A1

B2

1.5 m

max. 2 mm

2

1

B1

A1

B2

1.5 m

max. 2 mm

2

Содержание SK103P

Страница 1: ... Operation 2 Care and advice on operation 8 Transport 8 Technical data SK103P 9 Safety instructions 10 Start up Inserting replacing batteries Pull the battery cover outwards to unlock the battery compartment Open the battery compartment cover and insert the batteries observing the correct polarity Then press the battery compartment cover back down until it engages Insert the batteries observing th...

Страница 2: ...ode ON Switching on off ON Briefly press the On Set key 1 OFF Press and hold down the On Set key 1 Laser functions Pressing the On Set key 1 activates the following laser functions 3 Action SK103P not in Lock mode in Lock mode 1x only horizontal line only horizontal line 2x only vertical line only vertical line 3x horizontal and vertical line again as 1x 4x all points 5x all lines and points 6x ag...

Страница 3: ...h 3 in order to transport or tilt the instrument beyond the self levelling range When locked the pendulum is fixed and the self levelling function is deactivated Transportation and lock Self levelling Pulse To be able to detect the laser lines over long distances 15 m or in unfavourable lighting conditions a laser detector can be used The detector is able to locate the laser beam in Pulse mode eve...

Страница 4: ...4 Operation Makita SK103P en GB F I E P NL DK S N FIN J CN ROK PL HR H RUS CZ GR LT LV EST SLO SK M TR Applications SK103P Receiver available as accessory ...

Страница 5: ...5 Operation Makita SK103P en GB F I E P NL DK S N FIN J CN ROK PL HR H RUS CZ GR LT LV EST SLO SK M TR How to use the wall mount bracket ...

Страница 6: ... the horizontal laser line or laser dot and mark the position of the line or the dot on wall A A1 Rotate the instrument by 180 and mark the horizontal laser line or the laser dot in exactly the same way on wall B B1 Then place the instrument at the same elevation as close as possible to wall A and again mark the horizontal laser line or the laser dot on wall A A2 Rotate the instrument by 180 again...

Страница 7: ...m the marking If the difference does not exceed 3 mm then the SK103P is within tolerance Checking the accuracy of the vertical line Place the Lock switch 3 in the Unlocked position As reference use a plumb bob and attach it as close as possible to an approx 3 m high wall Position the instrument at a distance of approx 1 5 m from the wall at an elevation of approx 1 5 m Direct the instru ment at th...

Страница 8: ...within toler ance Should your SK103P be outside of the specified tolerance please contact an authorised dealership of Makita Display notices Falling below or exceeding the permissible temperature range The laser switches off and all symbols flash Outside of the self levelling range The laser beam is flashing Pendulum locked The laser beam is not levelled and the Lock symbol 4 lights up Care and ad...

Страница 9: ... V Protection class spray water dust IP 54 Operating temperature 10 C to 40 C Storage temperature 25 C to 70 C Dimensions H x D x W 111 x 117 x 72 mm Weight without batteries 470 g Tripod thread 1 4 Non metric unit system Range up to 50 ft Range with detector up to 197 ft Levelling accuracy 32 ft 1 8 Self levelling range 4 1 Accuracy of plumbing point 32 ft 1 8 Accuracy of horizontal line 32 ft 1 ...

Страница 10: ... laser dots Prohibited use Using the product without instruction Using outside the stated limits Deactivation of safety systems and removal of explanatory and hazard labels Opening of the equipment by using tools screw drivers etc as far as not specifically permitted for certain cases Carrying out modification or conversion of the product Deliberate dazzling of third parties also in the dark Inade...

Страница 11: ... in accordance with national or local regulations The product must not be disposed of with the household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unau thorised personnel WARNING Using a battery charger not recommended by Makita can destroy the batteries This can cause fire or explosions P...

Страница 12: ...n which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experi...

Страница 13: ... Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous CAUTION Looking into the laser beam may be hazardous to the eyes Labelling Wavelength 635 nm Maximum radiant output power for classif...

Отзывы: