Checking the accuracy of the horizontal line:
Place the Lock switch
3
in the "Unlocked" (
)
position.
Position the instrument approx. 5 m away from the wall.
Direct the instrument at the wall and switch on with the
On/Set key
1
. Activate the laser line with the On/Set key
1
and mark the intersection point of laser crosshairs on
the wall.
Swivel the instrument to the right and then to the left.
Observe the vertical deviation of the horizontal line from
the marking. If the difference does not exceed 3 mm,
then the SK103P is within tolerance.
Checking the accuracy of the vertical line:
Place the Lock switch
3
in the "Unlocked" (
)
position.
As reference, use a plumb-bob and attach it as close as
possible to an approx. 3 m high wall.
Position the instrument at a distance of approx. 1.5 m from
the wall at an elevation of approx. 1.5 m. Direct the instru-
ment at the wall and switch on with the On/Set key
1
. Acti-
vate the laser line with the On/Set key
1
. Rotate the instru-
ment and align it with the bottom of the plumb line. Now read
off the maximum deviation of the laser line from the top of the
plumb line. If the difference does not exceed 2 mm, then the
SK103P is within tolerance.
max.
3 mm
5 m
1.5 m
max.
2 mm