background image

Makita LD050P

Instrument Set-up

3

en

Display

Battery

Units

Area /

Volume

Min/Max

Measuring

Measuring

reference

Info

Addition /

Subtraction

Pythagoras

Memory

Main line

Insert batteries

+

+

-

-

i

To ensure a reli-
able use, do not 
use zinc-carbon 
batteries. 
Change batter-
ies when battery 
symbol is flash-
ing.

Содержание LD050P

Страница 1: ...ctions 5 Measuring single distance 5 Permament measuring 5 Add Subtract 5 Area 6 Volume 6 Pythagoras 2 point 7 Pythagoras 3 point 7 Memory 5 last results 8 Technical Data 9 Message Codes 10 Care 10 Safety Instructions 10 Areas of responsibility 10 Permitted use 11 Prohibited use 11 Hazards in use 11 Limits of use 11 Disposal 11 Electromagnetic Compatibility EMC 11 FCC statement applicable in U S 1...

Страница 2: ... a potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or appreci able material financial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in ...

Страница 3: ...Battery Units Area Volume Min Max Measuring Measuring reference Info Addition Subtraction Pythagoras Memory Main line Insert batteries i To ensure a reli able use do not use zinc carbon batteries Change batter ies when battery symbol is flash ing ...

Страница 4: ...ears with a number observe the instruc tions in section Message Codes Example Adjusting measuring reference Distance is measured from the front of the device 1 Distance is measured from the rear of the device standard setting 2 Distance unit setting 0 000m 0 00m 0 00ft 0 00 1 16 0 00in 0 1 16in Switch between the following units 2 sec ...

Страница 5: ... measuring time increases Permament measuring 1 2 sec 8 532 m Aim active laser at target 2 The last value mea sured is displayed Stops permanent measur ing 3 Add Subtract 7 332 m 1 The next meas urement is added to the previous one 2 1x 2x The next meas urement is sub tracted from the previous one 5 515 m 12 847 m 3 i The result is shown in the main line and the measured value above This process c...

Страница 6: ... sec ond target point 24 352 m2 5 i The result is shown in the main line and the measured value above Volume 1 2x 2 Aim laser at first target point 3 4 Aim laser at sec ond target point 5 6 Aim laser at third target point 78 694 m3 7 i The result is shown in the main line and the measured value above ...

Страница 7: ...ressing the meas uring key for 2 sec in the function acti vates automatically Minimum or Maxi mum measure ment Pythagoras 3 point 1 4x 2 Aim laser at up per point 3 4 Aim laser at rec tangular point 5 6 Aim laser at lower point 8 294 m 7 i The result is shown in the main line and the measured distance above Pressing the measuring key for 2 sec in the function activates auto matically Minimum or Ma...

Страница 8: ...Makita LD050P Measuring Functions 8 en Memory 5 last results 8 294 m 5 5 last results are displayed 1 5x 8 294 m 5 Navigates trough 5 last results 2 ...

Страница 9: ...distances above 30 m Distance measurement ISO 16331 1 Accuracy with favourable conditions 2 0 mm 0 08 in Accuracy with unfavourable conditions 3 0 mm 0 12 in Range with favourable conditions 50 m 164 ft Range with unfavourable conditions 35 m 115 ft Smallest unit displayed 1 mm 1 16 in Ø laser point at distances 6 30 mm 10 50 m General Laser class 2 Laser type 635 nm 1 mW Protection class IP54 dus...

Страница 10: ... is responsible for supplying the product including the User Manual in a completely safe condition The company above is not responsible for third party accessories Responsibilities of the person in charge of the instrument To understand the safety instructions on the product and the instructions in the User Manual To be familiar with local safety regula tions relating to accident prevention Always...

Страница 11: ... been subject to abnormal use and before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modifications not expressly approved could void the user s authority to operate the equipment Limits of use Refer to section Technical data The device is designed for use in areas permanently habitable by ...

Страница 12: ...ect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Laser classification The device produces visible laser beams which are emitted from the instrument It is a Class 2 laser product in accordance with IEC60825 1 2014 Radiation safety of laser products Laser Class 2 products Do not star...

Отзывы: