Off
Blinking
Lighted
Indicator lamps
Charge the
battery.
0% to 25%
25% to 50%
50% to 75%
75% to 100%
Remaining
capacity
The battery
may have
malfunctioned.
015658
NOTE:
•
Depending on the conditions of use and the
ambient temperature, the indication may differ
slightly from the actual capacity.
Speed adjusting dial
1
013560
The tool speed can be adjusted by turning the dial.
Higher speed is obtained when the dial is turned in the
direction of number 5, lower speed is obtained when it is
turned in the direction of number 1.
NOTE:
•
The speed adjusting dial can be turned only as far
as 5 and back to 1. Do not force it past 5 or 1, or
the speed adjusting function may no longer work.
•
Depending on the type and condition of caulking
material, the rod may get clogged when operating
with low speed. In that case set the speed
adjusting dial higher.
Overload warning lamp
1
013557
The warning lamp flickers in red when the tool is
overloaded. If the load reaches some point, the lamp
keeps lighting in red and the tool stops. To restart the
tool, release the trigger and pull the trigger again.
NOTE:
Check what causes the overload when the lamp flickers
or lights up. Change the parameter of the speed
adjusting dial lower, or increase the diameter of the
nozzle.
Switch action
CAUTION:
•
Before inserting the battery cartridge into the tool,
always check to see that the switch trigger
actuates properly and returns to the "OFF"
position when released.
•
When not operating the tool, push the trigger-lock
button from A side to lock the switch trigger in the
OFF position.
A
B
1
2
013559
To prevent the switch trigger from accidentally pulled,
the trigger-lock button is provided.
To start the tool, push the trigger-lock button from B side
and pull the switch trigger. Tool speed is increased by
increasing pressure on the switch trigger. Release the
switch trigger to stop.
After use, press in the trigger-lock button from A side.
1. Lock lever
2. Switch trigger
1. Warning lamp
1. Speed adjusting
dial