background image

 

R

epair

(1)  Replacing of armature

1) 

Loosen the tapping screw PT4 x25 for mounting the

housing R to remove the housing R, and the fan 60 for

cooling the motor will be exposed.

2) 

Loosen the tapping screw PT4 x25 for mounting the belt

cover to remove the belt cover.

3) 

Disconnect the holder cap and then remove the carbon

brush.

4) 

Remove the synchro belt 6-300 and steel plate.

Housing R

Tapping screw 

PT4x25(7 pieces)

Tapping screw 

PT4x25(4 pieces)

Belt cover

Fan 60

Отзывы: