background image

GEN 

– 16P – User Manual 

 

Page 4 of 22 

 

DANGER

 

RISK OF HOT SURFACES 

 

Contact  with  hot  surfaces,  such  as  engine’s  exhaust 

components, could result in serious burns. 

  During operation, touch only the control surfaces of generator. 

 

NEVER 

touch any part of the engine, alternator, or exhaust when the generator is in 

use or immediately after use, as these get hot and could burn. 

 

 

 

 

DANGER

 

EXHAUST FUMES CAN BE FATAL

 

 

TOXIC HAZARD

 

 

ALWAYS 

ensure that there is adequate ventilation when using the generator. 

 

ALWAYS 

position the generator so that the exhaust is pointing away from people or 

animals. 

 

NEVER 

use the generator indoors or in an enclosed area. 

 

GENERATOR POSITIONING FOR SAFE USE 

 

ALWAYS 

leave  at  least  a  1  metre  (3  foot)  gap  between  the  generator  and  any 

surrounding building or structure. 

 

ALWAYS 

ensure the generator is on a solid, flat surface. 

 

ALWAYS 

ensure the surrounding area is free from any material that could burn or be 

damaged by heat. 

 

NEVER 

move or tilt the generator whilst it is switched on. 

 

NEVER 

cover or enclose the generator whilst it is in use. 

 

NEVER 

use  the  generator  at  an  incline  above  20

o

  otherwise  the  engine  will 

malfunction whilst in operation.

 

 

NEVER

 attempt to lift or move the generator without the assistance of other persons 

or suitable lifting equipment. 

 

 

 

DANGER

 

RISK TO BREATHING 

  Running  engine  gives  off  Carbon  Monoxide,  an  odourless, 

colourless, poisonous gas. 

  Breathing Carbon Monoxide can cause nausea, fainting or death. 

  Some  chemicals  or  detergents  may  be  harmful  if  inhaled  or 

ingested, causing severe nausea, fainting, or poisoning. 

Содержание GEN-16P

Страница 1: ...r OPERATOR S MANUAL Rev 0919 Makinex 16kVA Generator GEN 16P 2x15A 1x20A 3P Outlet 2x15A 1x32A 3P Outlet...

Страница 2: ...8 OVERALL MACHINE DIMENSIONS 9 ALTERNATOR SPECIFICATIONS 9 INSTRUCTION FOR USE 10 BEFORE USE 10 OPERATING GENERATOR 12 MAINTENANCE 13 GENERAL RECOMMENDATIONS 13 GENERAL TROUBLESHOOTING 14 STORAGE 15...

Страница 3: ...tronic or mechanical including photocopying without express written permission from MAKINEX Any type of reproduction or distribution not authorised by MAKINEX represents an infringement of valid copyr...

Страница 4: ...on CAUTION CAUTION indicates a potential hazardous situation which if not avoided may result in minor or moderate injury WARNING WARNING indicates a potentially hazardous situation which if not avoide...

Страница 5: ...ALWAYS disconnect the generator when carrying out any maintenance ALWAYS ensure the generator reaches operating speed before connecting a load ALWAYS start the engine BEFORE connecting any appliances...

Страница 6: ...leave at least a 1 metre 3 foot gap between the generator and any surrounding building or structure ALWAYS ensure the generator is on a solid flat surface ALWAYS ensure the surrounding area is free f...

Страница 7: ...use any damaged electrical cord sets with the generator FIRE RELATED SAFETY PRECAUTIONS DANGER RISK OF EXPLOSION OR FIRE Fuel and its vapours are extremely flammable and explosive Fire or explosion ca...

Страница 8: ...TS IF YOU ARE NOT A QUALIFIED ELECTRICIAN ELECTRICAL HAZARD WARNING FAILURE TO PROPERLY CONNECT THE EQUIPMENT TO THE EARTHING CONDUCTOR WILL RESULT IN A RISK OF ELECTROCUTION CONSULT WITH A QUALIFIED...

Страница 9: ...GEN 16P User Manual Page 7 of 27 GENERAL SAFETY DECAL 1 4 7 2 5 8 3 6 9 10...

Страница 10: ...G DIMENSIONS 772 x 530x 902mm LENGTH x WIDTH x HEIGHT APPROX NOISE LEVEL 7m NO LOAD 72dB 50 LOAD 76dB 100 LOAD 78dB ENGINE TYPE TWIN CYLINDER AIR COOLED PETROL MODEL HONDA GX690 STARTING SYSTEM ELECTR...

Страница 11: ...GEN 16P User Manual Page 9 of 22 OVERALL MACHINE DIMENSIONS ALTERNATOR SPECIFICATIONS Dimensions in mm...

Страница 12: ...level with the engine stopped and in a levelled position 2 Start the engine and let it idle for 1 or 2 minutes Stop the engine and wait for 2 or 3 minutes 3 Remove the oil level dipstick and wipe it...

Страница 13: ...evere burns and even death FIRE HAZARD WARNING Always ensure that fuel tanks are filled outdoors 1 Turn generator OFF and let it cool for at least two minutes before removing fuel cap 2 Loosen fuel ca...

Страница 14: ...it there until the engine starts 5 When the engine starts release the engine switch allowing it to return to the ON position 6 Once the engine has warmed up set the choke lever to the OPEN position C...

Страница 15: ...intenance schedule is in the Honda GX690 owner s manual Should you have questions about replacing components on your generator please contact dealer for assistance MAKINEX dealers have access to all t...

Страница 16: ...lace or clean air filter Generator is overloaded Reduce the load Fault in alternator Contact authorised Makinex dealer Engine throttle is in SLOW position Slide the throttle to FAST position Engine re...

Страница 17: ...iefly turn the key starter for 1 2 seconds to distribute oil DO NOT start engine at this time WARNING Unintentional sparking can cause fire or electrical shock Failure to observe this warning can caus...

Страница 18: ...tions and exclusions printed on this page This warranty applies only to new MAKINEX generator distributed by us and by our authorised MAKINEX dealers Under the limited warranty and at MAKINEX s discre...

Страница 19: ...ved in an accident abused loaded beyond the generator s limits modified and installed improperly Normal maintenance such as spark plugs air filters adjustments fuel system cleaning and obstruction due...

Страница 20: ...rised staff or appointed agents at a premise to be determined by the Manufacturer It is the responsibility and cost of MAKINEX or our appointed agent to return the machine to be repaired or replaced u...

Страница 21: ...nex com au SERVICE SPARE PARTS WARRANTY EMAIL service makinex com au USA SALES TEL 1 855 625 4639 WEB www makinex com SERVICE SPARE PARTS WARRANTY EMAIL service makinex com UK WEB www makinex co uk EU...

Страница 22: ...GEN 16PQ User Manual Page 20 of 28 APPENDICES APPENDIX A WIRING CIRCUIT DIAGRAM...

Страница 23: ...GEN 16P User Manual Page 21 of 22 APPENDIX B RISK ASSESSMENT...

Страница 24: ...GEN 16P User Manual Page 22 of 22...