Introduction 

The 2-in-1 LAN Tester & Multimeter is an innovative tester 

that allows the user to easily measure DC/AC Voltage and 

Current, Resistance, Continuity, diode and verify the cable 

continuity; open short and cross-connect. The included 

remote terminator allows the user to test installed cable 

either at a wall jack or a patch panel adding up to value and 

convenience. Proper use and care of this meter will provide 

years of reliable service. 

 

Features: 

 

2-in-1 LAN Tester & Multimeter

 

  Measures DC/AC Voltage, DC/AC Current, Resistance, 

Continuity, diode and LAN tester 

 

3

½

 digit 

(2000 count) 

LCD display for multimeter functions

 

 

LED Displays the actual pin configuration of 10/100

 

BASE-T 

(Category 5) 

AND 10BASE-2 Thin Ethernet, 

RJ45/RJ11 modular, 258A, tia-568a/568b and Token 
Ring cables

 

 

Double Molded housing

 

 

CAT III 600V; CAT II 1000V

 

 

Provides easy to read continuity and fault status display

 

  Checks for continuity, open wire, ground wire, shorted 

pair and crossed pair faults 

 

Allows for remote testing of installed cables from wall 
jack

 

or patch panel

 

 

Auto or manual scanning for LAN tester

 

 

Autoranging with auto power off for multimeter functions

 

Содержание MTC50

Страница 1: ...Instruction Manual MTC50 2 in 1 LAN Tester Multimeter...

Страница 2: ...2 Contents Introduction 3 Features 3 Safety Precautions 4 Meter Description 5 Electrical Specification 6 Operation 8 Multi Network Modular Cable Tester 11...

Страница 3: ...ster Multimeter Measures DC AC Voltage DC AC Current Resistance Continuity diode and LAN tester 3 digit 2000 count LCD display for multimeter functions LED Displays the actual pin configuration of 10...

Страница 4: ...are properly closed and secured 3 Always disconnect the test leads from any voltage source before replacing the battery or fuses 4 Do not exceed the maximum rated input limits Input Limits Function M...

Страница 5: ...r with LED display for receiving end 2 Jack RJ45 3 LAN connector 4 Jack RJ45 5 Jack RJ45 6 Led display for sourcing end Jack 1 Led display for receiving end Jack 2 7 Test switch for auto scan 8 LAN te...

Страница 6: ...ications Function Range Accuracy DC Voltage 200mV 0 5 rdg 3d 2 000V 20 00V 1 0 rdg 3d 200 0V 600V 1 0 rdg 3d AC Voltage 50 60Hz 2 000V 20 00V 1 0 rdg 5d 200 0V 600V 1 5 rdg 10d DC Current 200 0 A 2000...

Страница 7: ...Battery Indication BAT symbol indicates low battery condition Input Impedance 7 5M VDC VAC AC Response Average responding ACV Bandwidth 50Hz to 60Hz Auto Power Off 15 minutes approximately Fuse mA A...

Страница 8: ...display AC DC CURRENT MEASUREMENTS 1 Set the function switch to the A mA position 2 Insert the black test lead into the negative COM terminal and the red test lead into the positive A mA terminal 3 Fo...

Страница 9: ...stance reading 4 Read the resistance in the display CONTINUITY CHECK WARNING To avoid electric shock never measure continuity on circuits or wires that have voltage on them 1 Set the function switch t...

Страница 10: ...gain to return to normal operation Hold Button The Data Hold function allows the meter to freeze a measurement for later reference 1 Press the DATA HOLD button to freeze the display the HOLD indicator...

Страница 11: ...e center board with the connectors and gently press into place 9 Replace and secure the rear cover battery and battery cover Multi Network Modular Cable Tester Operation The Multi Network Modular Cabl...

Страница 12: ...the top row 5 Read the results of the LED display for the pin configuration status of the tested cable If you fail to read the results the first time in Auto mode you may wait for the second LED scan...

Страница 13: ...switch to Auto mode for one person testing 3 Read the test results from the LED display on remote terminator Note The LED display on the remote unit will scan in sequence corresponding to the transmi...

Страница 14: ...14...

Отзывы: