Max input voltage   

600V AC/DC 

Diode Test 

Test  current 1mA max., open circuit 

voltage of 1.5V typical 

Continuity Check 

Audible signal if the resistance is 

<150

 

Display 

2000 count 3 -1/2 digit LCD 

Over range indication 

LCD displays “OL” 

Polarity 

Minus (-) sign for negative polarity. 

Low Battery Indication 

“BAT” symbol indicates low battery 

condition. 

Input Impedance 

>7.5MΩ (VDC & VAC)

 

AC Response 

Average responding 

ACV Bandwidth 

50Hz to 60Hz 

Auto Power Off 

15 minutes (approximately) 

Fuse 

mA, µA ranges; 0.2A/250V fast acting 

Fuse 

Batteries 

9V battery and two “AAA” batteries 

Operating Temperature 

 

32

o

F to 104

o

F (0

o

C to 40

o

C) 

Storage Temperature 

14

o

F to 122

o

F (-10

o

C to 50

o

C) 

Weight 

308g 

Size 

162x74.5x44.0mm 

Standard 

IEC1010  CAT III-600V Pollution 

degree II, CE Approved 

 

 

 

 

 

 

Содержание MTC50

Страница 1: ...Instruction Manual MTC50 2 in 1 LAN Tester Multimeter...

Страница 2: ...2 Contents Introduction 3 Features 3 Safety Precautions 4 Meter Description 5 Electrical Specification 6 Operation 8 Multi Network Modular Cable Tester 11...

Страница 3: ...ster Multimeter Measures DC AC Voltage DC AC Current Resistance Continuity diode and LAN tester 3 digit 2000 count LCD display for multimeter functions LED Displays the actual pin configuration of 10...

Страница 4: ...are properly closed and secured 3 Always disconnect the test leads from any voltage source before replacing the battery or fuses 4 Do not exceed the maximum rated input limits Input Limits Function M...

Страница 5: ...r with LED display for receiving end 2 Jack RJ45 3 LAN connector 4 Jack RJ45 5 Jack RJ45 6 Led display for sourcing end Jack 1 Led display for receiving end Jack 2 7 Test switch for auto scan 8 LAN te...

Страница 6: ...ications Function Range Accuracy DC Voltage 200mV 0 5 rdg 3d 2 000V 20 00V 1 0 rdg 3d 200 0V 600V 1 0 rdg 3d AC Voltage 50 60Hz 2 000V 20 00V 1 0 rdg 5d 200 0V 600V 1 5 rdg 10d DC Current 200 0 A 2000...

Страница 7: ...Battery Indication BAT symbol indicates low battery condition Input Impedance 7 5M VDC VAC AC Response Average responding ACV Bandwidth 50Hz to 60Hz Auto Power Off 15 minutes approximately Fuse mA A...

Страница 8: ...display AC DC CURRENT MEASUREMENTS 1 Set the function switch to the A mA position 2 Insert the black test lead into the negative COM terminal and the red test lead into the positive A mA terminal 3 Fo...

Страница 9: ...stance reading 4 Read the resistance in the display CONTINUITY CHECK WARNING To avoid electric shock never measure continuity on circuits or wires that have voltage on them 1 Set the function switch t...

Страница 10: ...gain to return to normal operation Hold Button The Data Hold function allows the meter to freeze a measurement for later reference 1 Press the DATA HOLD button to freeze the display the HOLD indicator...

Страница 11: ...e center board with the connectors and gently press into place 9 Replace and secure the rear cover battery and battery cover Multi Network Modular Cable Tester Operation The Multi Network Modular Cabl...

Страница 12: ...the top row 5 Read the results of the LED display for the pin configuration status of the tested cable If you fail to read the results the first time in Auto mode you may wait for the second LED scan...

Страница 13: ...switch to Auto mode for one person testing 3 Read the test results from the LED display on remote terminator Note The LED display on the remote unit will scan in sequence corresponding to the transmi...

Страница 14: ...14...

Отзывы: