Overrange Indication  

"OL" is displayed 

Measurements Rate  

2 per second, nominal 

Input Impedance  

≥10MΩ (VDC and VAC) 

Display  

6000 counts LCD 

AC Current  

50-60Hz (AAC) 

AC Voltage bandwidth   50-1000Hz (VAC) 
Operating Temperature   5 to 40°C (41 to 104°F)
Storage Temperature  

-20 to 60°C (-4 to 140°F) 

Operating Humidity  

Max 80% up to 31°C (87°F) decreasing linearly 

to 50% at 40°C (104°F) 

Storage Humidity  

<80% 

Operating Altitude  

2000 meters (7000ft.) maximum. 

Over voltage  

Category III 1000V, Category IV 600V. 

Battery  

3x "AAA" 1.5V Battery 

Auto OFF 

approx. 15 minutes 

Safety  

For indoor use and in accordance with Over 

voltage Category II, Pollution Degree 2. 
Category II includes local level, appliance, 
portable equipment, etc., with transient over 

 

 

voltages less than Over voltage Cat. III  

Range

Basic Functions

4.11. General Specifications (continued)

5.1. AC/DC Current Measurements 

1.  Set the Function switch to the 

600A AC/DC, 

60A AC/DC

 range. 

2.  Press MODE to switch the AC/DC measurement.  
3.  If the range of the measured is not known, 

select the higher range first then move to the 
lower range if necessary. 

4. Press the trigger to open jaw. Fully enclose one 

conductor to be measured. The clamp meter 
LCD will display the reading. 

NOTES: 

Read and understand all Warning and Caution statements in 

this operation manual prior to using this meter. Set the function select 
switch to the OFF position when the meter is not in use. 

5. OPERATION

 

WARNING:

 Ensure that the test leads are disconnected from the meter 

before making current clamp measurements. 

Содержание MT766

Страница 1: ...MT766 600A AC DC CLAMP METER WITH IR THERMOMETER INSTRUCTION MANUAL...

Страница 2: ...2...

Страница 3: ...Temp type K 7 4 10 IR Temp D S 4 1 7 4 11 General Specifications 7 5 Operation 8 5 1 AC DC Current Measurements 8 5 2 AC DC Voltage Measurement 9 5 3 Resistance Measurements 9 5 4 Diode Continuity and...

Страница 4: ...his meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery Inspect the condition of the...

Страница 5: ...de 9 Units of measure list AC DC 8 8 8 8 AUTO HOLD C F u m V A K M 3 DISPLAY ICONS 9 Rotary Function switch 10 Data Hold Flashlight button 11 Non contact AC voltage indicator light 12 Non contact AC v...

Страница 6: ...ing digits 600 0 1 5 6 digits 6 000K 2 0 5 digits 60 00K 600 0K 2 8 10 digits 6 000M 60 00M 2 8 10 digits Range Resolution 4 5 Resistance Accuracy of reading digits 999 9nF 9 999 F 4 reading 6 digits...

Страница 7: ...racy index of the current measured outside the measuring range increased by 1 5 and the accuracy of other measurement functions increased by 1 Check waveform is sine wave Current accuracy assessment s...

Страница 8: ...l level appliance portable equipment etc with transient over voltages less than Over voltage Cat III Range Basic Functions 4 11 General Specifications continued 5 1 AC DC Current Measurements 1 Set th...

Страница 9: ...nto the negative COM jack and the red test lead banana plug into the positive diode jack 2 Set the function switch to the position 3 Press the MODE button until appears in the display 4 Touch the test...

Страница 10: ...roper decimal point and value WARNING To avoid electric shock disconnect both test probes from any source of voltage before making a temperature measurement WARNING To avoid electric shock be sure the...

Страница 11: ...he testing range Press once to select MIN press again to select MAX lastly press again to release the MIN MAX recording function 5 13 VFD Button In ACV mode hold down the mode key to enter the VFD mea...

Страница 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: