6.7. DIODE TEST  

WARNING:

 To avoid electric shock, disconnect power to the unit 

under test and discharge all capacitors before taking any capacitance 
measurements. Remove the batteries and unplug the line cords. 

 

1. Set the function switch to the Ω CAP          position. 
2. Insert the black test lead banana plug into the negative 

COM

 jack and the red test lead banana plug into the 

positive V jack. 

3. Press the 

MODE

 button to indicate "    " and "

V

" on the 

display. 

4. Touch the test probes to the diode under test.  Forward 

voltage will typically indicate 0.400 to  0.700V. Reverse 
voltage will indicate "

OL

". Shorted devices will indicate 

near 0V and an Open device will indicate "

OL

" in both 

polarities. 

6.8. CAPACITANCE MEASUREMENTS  

1. Set the rotary function switch to the Ω CAP          

position. 

2. Insert the black test lead banana plug into the negative 

COM

 jack. 

3. Insert the red test lead banana plug into the positive 

V

 

jack. 

4. Touch the test leads to the capacitor to be tested. Read 

the capacitance value on the display 

 

 

6.9. TEMPERATURE MEASUREMENTS  

1. Set the function switch to the "Temp" positive and 

press the MODE key to select the "°C" measuring 
or "°F" measuring. 

2. Insert the Temperature Probe into the input jacks, 

making sure to observe the correct polarity. 

3. Touch the Temperature Probe head to the part 

whose temperature you wish to measure .Keep the 
probe touching the part under test until the reading 
stabilizes (about 30 seconds). 

4. Read the temperature on the display. 

Note:

 The temperature probe is fitted with a type K 

mini connector. A mini connector to banana connector 
adaptor is supplied for connection to the input banana 
jacks. 

 

14 

 
TEMPERATURE MEASUREMENTS 

1.  Set the function switch to the “Temp” 
positive and press the MODE key to select 
the “°C” measuring or “°F” measuring. 

 

2.  Insert the Temperature Probe into the    

input  jacks,  making  sure  to  observe  the       

correct polarity. 
3.  T ouch  the  Temperature  Probe head  to    
the  part  whose 

temperature  you  wish  to 

measure .Keep the  probe touching the  part 
under  test  until  the  reading       stabilizes 
(about 30 seconds). 
4.  Read the temperature in the display. 

 

Note:

 The temperature probe is fitted with a type K mini connector.  

A mini connector to banana connector adaptor is supplied for  
connection to the input banana jacks. 

FREQUENCY MEASUREMENT 

1.  

Set the function switch to the Hz/Duty position. 

2.  

Insert  the  black  test  lead  banana  plug  into  the  negative 
( -  )  jack  (COM)  and  the  red  test  lead  banana  plug  into 
the positive ( + ) jack ( F ). 

3.  

Touch the test probe tips to the circuit under test. 

 

 

Содержание MT1882

Страница 1: ...INSTRUCTION MANUAL 1000V AC DC TRMS MULTIMETER IV MT1882 ...

Страница 2: ...2 ...

Страница 3: ...9 Temperature Measurements 11 6 10 Frequency Measurement 12 6 11 Mode Button 12 6 12 Data Hold Button 12 6 13 Range Button 12 6 14 Min Max Button 13 6 15 Low Battery Indication 13 7 Maintenance 13 7 1 Battery Installation 14 8 Specifications 14 8 1 DC Voltage 14 8 2 AC Voltage Auto ranging 14 8 3 AC Voltage VFD 15 8 4 DC Current Auto ranging 15 8 5 AC Current Auto ranging 15 8 6 Resistance Auto ra...

Страница 4: ...ect to earth ground exceeds in this case 1000 VAC or VDC This symbol adjacent to one or more terminals identifies them as being associated with ranges that may in normal use be subjected to particularly hazardous voltages For maximum safety the meter and its test leads should not be handled when these terminals are energized This symbol indicates that a device is protected throughout by double ins...

Страница 5: ...rth 4 NEVER connect the meter leads across a voltage source while the function switch is in the current resistance or diode mode Doing so can damage the meter 5 ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests 6 ALWAYS turn off the power and disconnect the test leads before opening the covers to replace the fuse or batteries 7 NEVE...

Страница 6: ...z button 3 RANGE button 4 MODE button 5 Function switch 6 mA μA and 10A input jacks 7 COM input jack 8 Positive input jack 9 Backlight and Hold button 10 MAX MIN button 11 REL button Note Tilt stand and battery compartment are on rear of unit V A mA V V ...

Страница 7: ...imum Auto Range Timing symbol Backlight Bargraph Volts Frequency Conversion Measure Auto ranging Display hold Minimum Degrees Fahrenheit Degrees Centigrade 6 OPERATING INSTRUCTIONS WARNING Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care 1 ALWAYS turn the function switch to the OFF position when the meter is not in use 2 If OL app...

Страница 8: ...ert the black test lead banana plug into the COM input jack insert the red test lead banana plug into the Positive input jack 3 Position the black test probe tip and red test probe tip respectively in the spots of the circuit to be measured 4 Read the voltage on the display 5 Press and hold the MODE Button key for 2 seconds to indicate VFD on the display 6 Read the VFD value on the display 7 To ex...

Страница 9: ...Connect the black test probe tip and the red test probe tip in series to the circuits current you want to measure 8 Apply power to the circuit 9 Read the current on the display 6 4 AC CURRENT FREQUENCY DUTY CYCLE MEASUREMENT CAUTION Do not make 10A current measurements for longer than 30 seconds Exceeding 30 seconds may cause damage to the meter and or the test leads 1 Insert the black test lead b...

Страница 10: ...e COM jack Insert the red test lead banana plug into the positive Ω jack 3 Press the MODE button to indicate Ω on the display 4 Touch the test probe tips across the circuit or part under test It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 5 Read the resistance on the display 6 6 CONTINUITY CHECK WARNING To avoid el...

Страница 11: ...NTS 1 Set the rotary function switch to the Ω CAP position 2 Insert the black test lead banana plug into the negative COM jack 3 Insert the red test lead banana plug into the positive V jack 4 Touch the test leads to the capacitor to be tested Read the capacitance value on the display 6 9 TEMPERATURE MEASUREMENTS 1 Set the function switch to the Temp positive and press the MODE key to select the C...

Страница 12: ...es until you select the range you want 3 Press and hold the RANGE button for 2 seconds to Exit the Manual Ranging mode and return to Auto Ranging 6 12 DATA HOLD BUTTON The Data Hold function allows the meter to freeze a measurement for later reference 1 Press the DATA HOLD button to freeze the reading on the indicator The indicator HOLD will be appear in the display 2 Press the DATA HOLD button to...

Страница 13: ...ccasionally with a damp cloth DO NOT use chemicals cleaning solvents or detergents 5 USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME the batteries should be removed to prevent damage to the unit 6 14 MIN MAX BUTTON The meter displays the maximum or minimum value o...

Страница 14: ... Input 1000V DC or 1000V AC RMS 7 1 BATTERY INSTALLATION WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery cover 1 Turn power off and disconnect the test leads from the meter 2 Open the rear battery cover by removing two screws B using a Phillips head screwdriver 3 Insert the battery into battery holder observing the correct polarity 4...

Страница 15: ...uA 1 5 of reading 3 digits 6000uA 1uA 60 00mA 0 01mA 600 0mA 0 1mA 6 000A 0 001A 2 0 of reading 3 digits 10A 0 01A 8 5 AC CURRENT AUTO RANGING All AC Current ranges are specified from 5 of range to 100 of range Overload Protection FF800mA 1000V and F10A 1000V Fuse AC Response 50 Hz to 400 Hz Maximum Input 6000uA AC RMS on uA 800mA AC RMS on mA 10A AC RMS on 10A range Range Resolution Accuracy 50 0...

Страница 16: ...ading 4 digits 99 99 Hz 0 01Hz 999 9 Hz 0 1Hz 9 999KHz 1 Hz 99 99kHz 10Hz 999 9kHz 100Hz 9 999MHz 1kHz 10 00MHz 0 01MHz 8 8 FREQUENCY ELECTRONIC AUTO RANGING Sensitivity 0 5V RMS while 1MHz Sensitivity 3V RMS while 1MHz Input Protection 250V DC or 250V AC RMS Range Resolution Accuracy 600 0Ω 0 1Ω 1 0 of reading 2 digits 6 000kΩ 0 001kΩ 0 8 of reading 2 digits 60 00kΩ 0 01kΩ 600 0kΩ 0 1kΩ 6 000MΩ 0...

Страница 17: ... elements reading This is the accuracy of the measurement circuit digits This is the accuracy of the analog to digital converter Note Accuracy is stated at 18 to 28 C 65 to 83 F and less than 75 RH 17 Range Resolution Accuracy 10 00 1KHz 0 01Hz 1 5 reading 8 9 FREQUENCY ELECTRICAL Sensitivity ACmV Range 100mV ACV Range 6 Range 6000μA 600 0mA 10 00A Range 6 Range 600 0μA 60 00mA 6 000A 60 Range Ran...

Страница 18: ...ess than 50Ω approx test current 1mA Temperature Sensor Requires type K thermocouple AC Response True RMS ACV Bandwidth 50Hz to 400Hz Crest Factor 3 at full scale up to 500V decreasing linearly to 1 5 at 1000V Display 6000 count backlit liquid crystal with bargraph Overrange indication OL is displayed 8 13 AUDIBLE CONTINUITY Audible threshold Less than 50Ω Test current MAX 1mA Overload protection ...

Страница 19: ...rage Humidity 80 Operating Altitude 2000meters 7000ft maximum Weight 342g 0 753lb includes holster Size 187 x 81 x 50mm 7 36 x 3 2 x 2 0 includes holster Safety This meter is intended for origin of installation use and protected against the users by double insulation per EN61010 1 and IEC61010 1 2nd Edition 2001 to Category IV 600V and Category III 1000V Pollution Degree 2 The meter also meets UL ...

Страница 20: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia ...

Отзывы: