10
14
8. SPECIFICATIONS
Range
Resolution Accuracy
600.0mV 0.1mV
±
0.5% of reading
±
5digits
6.000V
0.001V
60.00V
0.01V
600.0V
0.1V
1000V
1V
±
0.6% of reading
±
6 digits
8.1. DC VOLTAGE
Input Impedance: approx. 10MΩ.
Maximum Input: 1000V DC or 1000V AC RMS.
Range
Resolution Accuracy
6.000V
0.001V
±
0.8%of reading
±
4digits
60.00V
0.01V
600.0V
0.1V
1000V
1V
±
0.8%of reading
±
8 digits
8.2. AC VOLTAGE (AUTO-RANGING)
All AC voltage ranges are specified from 5% of range to 100% of range
Input Impedance: approx 10MΩ.
AC Response: 50 Hz to 400Hz
Maximum Input: 1000V DC or 1000V AC RMS.
7.1. BATTERY INSTALLATION
WARNING:
To avoid electric shock, disconnect the test leads from
any source of voltage before removing the battery cover.
1. Turn power off and disconnect the test leads from the meter.
2. Open the rear battery cover by removing two screws (B) using a
Phillips head screwdriver.
3. Insert the battery into battery holder, observing the correct polarity.
4. Put the battery cover back in place. Secure with the screws.
WARNING:
To avoid electric shock, do not operate the meter until
the battery cover is in place and fastened securely.
NOTE:
If your meter does not work properly, check the fuses and
batteries to make sure that they are still good and that they are properly
inserted.