background image

18

ODSHR Outdoor Woodburning Fireplace

20002264

Installing Line for Gas Logs

CFM Corporation fireplaces are designed to accept a 
1/2 inch gas line for installation of an approved gas ap-
pliance.  (CFM Corporation manufactures a wide variety 
of gas logs for use in Majestic Fireplaces units.)
Be sure to have the appliance installed in accordance 
with building codes.  
Gas connection may enter from either left or right side 
of the fireplace.
Locate appropriate gas line in the outer casing of fire-
place and remove insulation from gas line tube. (Fig. 
32)
From inside the fireplace, locate the knockout on the 
firebrick -- be sure you are on the appropriate or "gas 
line" side of the fireplace.  Using a flat bladed screw-
driver or small chisel and hammer, carefully tap around 
the knockout until it loosens and falls out.
Install 1/2 inch certified gas pipe through opening.  
After gas pipe installation is complete, use insulation 
that was removed from gas line tube to repack space 
around the pipe.  Material should be inserted from 
outside of the fireplace and packed tightly to totally seal 
between the pipe and tube.

NOTE:  Gas pipe should not come in contact with 
any wood structures until it has reached a point at 
least one (1) inch away from fireplace side. 
NOTE:

 When installing an ANSI Z21.11.2 ventless ap-

pliance, the finishing material used for the mantel must 
be rated at 250°F or greater.

FP1172
sealing detail 2
12/20/01   djt 

2 x 4 Header 

- Do Not Notch at 

Ledge Brackets

Fig. 19

Wall Covering

Noncombustible 

Decorative Facing

Seal All Cracks 

Between Fireplace 

Surround and Wall 

Materials with 

Noncombustible 

Material

Noncombustible 

Decorative Cover-

ing

Majestic Safety Strips 

Must be Overlapped 1/2" 

Min.

Seal Crack Between Fire-

place and Hearth Exten-

sion with Noncombustible 

Material

FP1172

Fig. 31 

 Sealing detail.

Hearth 

Extension

BTU input of a gas appliance installed in fireplace 
should be rated less than 100,000 BTU/Hr.
Gas pipe installation is intended for connection to a 
decorative gas appliance only when (1.) incorporating 
an automatic shutoff device and (2.) complying with the 
Standard for Decorative Gas Appliances for Installa-
tion in Vented Fireplaces (ANSI Z21.60) 

or 

CSA draft 

requirements for Gas-Fired Log Lighters for Woodburn-
ing Fireplaces (Draft No. 4, August 1993). 
Decorative gas appliance should be installed in accor-
dance with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 (latest edition).

CAUTION:  WHEN USING DECORATIVE 
GAS APPLIANCE, FLUE DAMPER MUST 
BE SET IN FULLY OPEN POSITION.  IF YOU 

HAVE GLASS DOORS ON THE FIREPLACE, 
THEY MUST ALSO BE FULLY OPENED.

WARNING: DO NOT OPERATE AN 
UNVENTED GAS LOG SET IN THIS FIRE-
PLACE WITH THE CHIMNEY REMOVED.

WARNING: WHEN INSTALLING AN 
UNVENTED GAS LOG SET, THE CFM 
CORPORATION MODEL AH3244BK OR 
AH3244PB 4" ADJUSTABLE HOOD MUST 

BE USED.

OUTSIDE INSTALLATION: ONLY USE THE 
OD30CFLN/P VENTED GAS LOG SET.

Only unvented gas log sets which have been found to comply 
with the Standard for Unvented Room Heaters, ANSI Z21.11.2, 
are to be installed in this fireplace.

If installing an unvented gas log set, refer to statement below:

1"

Min.

FP560SHR

SHR series

5/12/99   djt

1/2"

FP560SHR

Fig. 32 

  Gas line access.

Hole in Outer 

Casing

Gas Line 

Tubing

Ceramic 

Knockout

Hole in 

Outer 

Casing

Supply 

Line

Repack 

Insulation

Ceramic 

Knockout

(both sides)

Содержание Vermont Castings ODSHR42

Страница 1: ...djt Homeowner s Installation and Operating Manual DO NOT DISCARD THIS MANUAL Retain for future use 20002264 10 06 Rev 17 Model ODSHR42 Underwriter s Laboratories Report No MH20546 ODSHR Series Outdoor...

Страница 2: ...re hazard and will void the warranty Safety Information 2 Speci cations and Framing Dimensions 3 Hearth Dimensions 4 Chase Installations 5 Freestanding Installation 5 Chimney Requirements 6 Planning...

Страница 3: ...e replace to cook or warm food Do not obstruct or modify air inlets outlets in any manner Do not install combustible materials on any of the replace surround Burn only solid wood fuel or gas logs Do n...

Страница 4: ...Air Gas Line Access Gas Line Access 62 1578 mm 340 mm 279 mm Fig 1 ODSHR42 Series speci cations and framing ODSHR42 Series Woodburning Fireplace A B C FP1531 hearth dimensions 9 04 djt Front Width Ba...

Страница 5: ...FP1001 fireplace setting 1 4 00 djt NOTE If the replace is a free standing unit it must be located a minimum of 10 3 m from the opening of the rebox to a com bustible structure A minimum height of 6...

Страница 6: ...ured from the hearth to the chimney exit ODSHR42 Maximum 90 27 4 m Minimum Without Elbows 14 6 4 4 m With 2 Elbows 15 6 4 7 m With 4 Elbows 21 0 6 4 m B Do not use more than 4 elbows per chimney Attac...

Страница 7: ...will be set and how the chimney system will be run Mounting the Fireplace A replace may only be mounted on the following sur faces 1 A at combustible surface 2 A raised wooden platform 3 A concrete bl...

Страница 8: ...e in a cold climate it is not required but highly recommended that you insulate replace enclosure to eliminate cold air penetration as much as possible Insulate base of replace with a noncombustible i...

Страница 9: ...CK THE END CONNECTION OF CHIMNEY SECTIONS AND ELBOWS NOTE ODSHR Series Fireplaces must use CFM Cor poration model 11CF 11 inch 2 wall chimney systems The installation procedure described in this manua...

Страница 10: ...bers Chimney Hole Size FP551b SHR 5 11 99 djt New Framing Members Existing Ceiling Joists Chimney Hole 17 445 mm 17 445 mm FP551b Fig 13 Typical frame for ceiling chimney hole Fig 12 Ceiling chimney h...

Страница 11: ...re place are noncombustible Four 4 nailing anges are supplied with the replace found on the replace hearth To level the box and secure it rmly in place remove the nailing anges from the hearth and ins...

Страница 12: ...o chimney pipe for ceiling thickness up to 8 203 mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 203 mm adjust ments must be made in framing to assure that...

Страница 13: ...ize of roof hole There must be a 2 51 mm air space between out ermost portion of chimney sections and any adjacent combustible surfaces Combustible surfaces include burnable materials such as ceiling...

Страница 14: ...djt Air Space Clearances Combustible framing material MUST NOT pen etrate AIR SPACE shaded areas Standoff 2 Air Space to Sides Firestop Front View Side View Wall Shield Air Space to Back Air Space to...

Страница 15: ...ff Noncombustible Material Surround Face Fireplace Opening Noncombustible Facing Material Must be sealed with non combustible material Ledge Bracket Finished Wall 2 x 4 Stud Finished Wall Must be seal...

Страница 16: ...ensions FP838 Minimum Wall Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Minimum Hearth Extension Dimensions for On Site Construction 12 20 12 66 Seal cracks be...

Страница 17: ...acent combustible side walls and hearth extension dimensions FP1171 sealing detail 12 20 01 djt Wall Covering 2 x 4 Header Do Not Notch at Ledge Brackets Fig 20 Hearth Extension Hearth Extension Insul...

Страница 18: ...place Surround and Wall Materials with Noncombustible Material Noncombustible Decorative Cover ing Majestic Safety Strips Must be Overlapped 1 2 Min Seal Crack Between Fire place and Hearth Exten sion...

Страница 19: ...djt 1 2 5 7 6 4 3 12 11 8 10 9a b 13 Ref Description Part Number 1 Damper Blade 3990185 2 Damper Handle 20001418 3 Screen Rail 20002262 4 Screen Rod 20002222 5 Screen two per replace 20002223 6 Scree...

Страница 20: ...ustion in the rebox This accessory must be installed before replace is installed Located on the oor in front of replace to protect the oor from heat hot embers ashes etc Used to patch cracks in hearth...

Страница 21: ...se with CF11 pipe RLTCF11L 11 ue 11CF1 1 long 11CF18 1 long 11CF3 3 long 11CF4 4 long 11CF30 2 11 30 ue S20BR BT BW S20UB Upper Baf e 20002673 FS2100 HT Contact the CFM Corporation with questions con...

Страница 22: ...22 ODSHR Outdoor Woodburning Fireplace 20002264...

Страница 23: ...y is extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed according to the in stallation instruction...

Страница 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: