background image

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

1

Unvented Decorative Gas Fireplaces
P/N  903302  REV. M  12/2007

VF5000-CMN-2

VF6000-CMN-2

VF5000-CMP-2

VF6000-CMP-2

MODELS

STANDARD SERIES

INSTALLATION AND
OPERATING INSTRUCTIONS

FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM
HEATERS.

DO NOT BUILD A WOOD FIRE.

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicinity
of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.

CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE UNVENTED ROOM HEATER FOR
THE MINIMUM FIREPLACE SIZE REQUIREMENT.

DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UN-
LESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS
REQUIRED FOR THE INSTALLATIONS.

This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided.  Refer to Combustion
and Ventilation Air Section, Page 3.

Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.

Do not place clothing or other materials on or near this appli-
ance.

IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR UNVENTED ROOM
HEATERS.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL-
TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL.
FOR ASSISTANCE OR ADDITIONAL INFORMATION CON-
SULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE
GAS SUPPLIER.

WARNING: DO NOT BURN WOOD OR OTHER MATERIAL IN
THESE APPLIANCES.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.

INSTALLER:  Leave this manual with the appliance.
CONSUMER:  Retain this manual for future reference.

US

Содержание VF5000-CMN-2 and

Страница 1: ... NOT INSTALL THE APPLIANCE IN THIS FIREBOX UN LESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATIONS This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventila tion air must be provided Refer to Combustion and Ventilation Air Section Page 3 Due to high temperatures the appliance should be loca...

Страница 2: ...ning and Servicing page 12 Accessories Components page 12 Appliance Specifications page 14 Troubleshooting Guide page 15 Operating Instructions page 16 Replacement Parts List page 18 Replacement Parts page 19 Valve Regulator Pressure Gas Inlet Model No Gas Type Maximum BTU HR Operation Ignition Setting Pressure VF5000 CMN 2 Natural 25 000 Manual Piezo 5 w c Max 10 w c Min 6 w c VF5000 CMP 2 Propan...

Страница 3: ...urner and logs will increase the amount of carbon monoxide formation and could lead to carbon monoxide poisoning and death CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223 1 or NFPA54 which can be obtained from The American National Standards Insti tute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batt...

Страница 4: ...struc tion RefertoFigure1 forlocationsuggestions 4 Compare the maximum BTU Hr the space can support with the actual amount of BTU Hr used _________ BTU Hr max the space can support _________ BTU Hr actualamountofBTU Hrused Example 61 440 BTU Hr max the space can support 66 000 BTU Hr actualamountofBTU Hrused The space in the above example is a confined space because the actual BTU Hr used is more ...

Страница 5: ... INGHEATERNEXTTOVINYLORCLOTHWALL COVERINGS OR OPERATING HEATER WHERE IMPURITIES IN THE AIR SUCH AS TOBACCO SMOKE EXISTS MAY DISCOLOR WALLS Step 1 Position heater in desired location freestanding onto surround base or into pre pared framing and secure Step2 Plumbgasline Gasconnectionsshould onlybeperformedbyanexperienced licensed certified tradesman Step 3 Assemble logs and test flame appear ance S...

Страница 6: ...NSTALLATION STEPS Built In Systems WARNING DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS WARNING DO NOT USE A BLOWER IN SERT HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS HEATER Do not burn solid fuels in this listed unvented gas room heater Step 1 Frame VF5000 appliance enclosures as illustrated in Figures 4 5 and...

Страница 7: ...emote wall switch Step 7 Installing the Optional Forced Air Blower Kit Wiring A receptacle plate is pro videdfortheinstallationoftheFAB 1100forced air blower kit optional Electrical power must be provided to this plate to operate the blower Route a 3 wire 120Vac power line with control switch to the lower left front corner of the appliance Supply wires are to be connected to the outlet as shown in...

Страница 8: ...lianceinstallationoratanytimethere after Follow the instructions provided with the blower kit Finished Wall Details It is sometimes best to frame the appliance afterithasbeenpositionedinplace Framewith 2 x 4s or heavier lumber Always frame in accordance with local building codes Note The header may rest on the top spacers but must not be notched to fit around them Inordertoinstalltheappliancefacin...

Страница 9: ...ERS THISMAY CAUSE SOOTING Connecting Gas Line Step 11 A qualified gas appliance installer must connect the gas room heater to the gas supply Consult all local codes and refer to Step 5 The heater gas inlet connection is 3 8 NPT located on the left side facing the heater If a right side connection is required the connec tion pipe may be piped under the rear of the appliance to end at the left hand ...

Страница 10: ...ur homes unique needs Kit part numbers are provided on pages 16 and 17 along with descriptive illustrations The appliances covered in this manual are heater rated and produce a great deal of heat Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face Tarnishing of these pieces is normal unavoidable and should be expected Forced Air Kit Th...

Страница 11: ...signed to be fitted to your appli ance above the door In addition to providing an aesthetically pleasing appearance to your appliance installation the hood reduces heat effects to decorative mantles and finish mate rials located directly above the fireplace open ing The hood kit includes the necessary attaching hardware This kit can be retrofitted to previously installed appliances Solid Brass Lou...

Страница 12: ...tructionsarealsofound on a pull out panel located on the floor of the appliance 7 Alwayskeeptheapplianceareaclearandfree fromcombustiblematerials gasolineandother flammable liquids 8 Remember this appliance has a continuous burning pilot flame Exercise caution when using products with combustible vapors CLEANING AND SERVICING WARNING TURN OFF THE UNVENTED GAS ROOM HEATER AND ALLOW TO COOL BEFORE C...

Страница 13: ... Kit VF6RLK Decorative Volcanic Stone FDVS VF5 PBH Brass Hood Kit VF6 PBH VF5 BRLK Brass Louver Kits VF6 BRLK DAT 5 1 2 Piece Decorative DAT 5 4 Arch Frame Kits DAT 6 1 BSK 5 BSK 6 Brass Square STK 6 4 Surround Kits STK 5 4 Thermostat WTK ACCESSORIES AND COMPONENTS Wood Surround Wall SUR 5PW Wood Surround Corner SUR 5PC ...

Страница 14: ...s Line Opening J Box Opening Left Side Only 8 203 mm 3 3 4 95 mm 3 1 2 89 mm 15 1 2 394 mm 1 2 13 mm 5 1 2 140 mm 3 76 mm 37 940 mm 31 1 2 800 mm 42 1 8 1070 mm 40 1016 mm 34 864 mm 36 7 8 937 mm 20 508 mm Front View 40 1016 mm 19 1 2 495 mm Top View 28 1 2 724 mm Left Side View Right Side View Opposite Gas Line Opening 11 279 mm 19 1 2 495 mm 1 2 13 mm 5 1 2 140 mm J Box Opening Left Side Only 3 ...

Страница 15: ... orifice Replace burner Replace gas regulator Problem will stop after a few hours of operation SFC recommends running the heater with excess ventilation for the first few hours Turn control knob to LO position and let warm up for a minute Operateburneruntilairisremovedfromline Havegaslinecheckedbylocalgas company Clean burner or replace burner orifice A Igniter electrode positioned wrong B Igniter...

Страница 16: ...d the safety information above on this page 2 Access left side louver 3 Turn remote wall switch to OFF 4 Verify main line shut off valve is open 5 Push in gas control knob slightly and turn clockwise to OFF Note Knob cannot be turned from PILOT to OFF unless the knob is pushed in slightly Do not force 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety info...

Страница 17: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 17 NOTES ...

Страница 18: ...10344 1 Pilot Propane LPG 901915 1 901915 1 4 Regulator Natural 903218 1 903218 1 Regulator Propane LPG 112081 1 112081 1 5 Front Burner 110281 1 110282 1 6 Rear Burner Natural 113301 1 110302 1 Rear Burner Propane LPG 113301 1 110302 1 7 Crossover Burner 110321 1 110321 1 8 Injector Crossover Burner Natural 110387 1 110387 1 Injector Crossover Burner Propane LPG 110388 1 110388 1 9 Piezo 111061 1...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 19 REPLACEMENT PARTS 9 10 3 15 14 4 7 6 5 16 13 1 12 SIT Valve Shown 14 2 8 11 ...

Страница 20: ...903302 REV M 12 2007 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue Orange CA 92865 ...

Отзывы: