2

STR Series Woodburning Fireplaces

7412961

Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.
IMPORTANT: 

Read all instructions and warnings carefully before starting installation.  Failure to 

follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The STR Series fireplaces are multi-side solid fuel, wood-
burning fireplaces. These are radiant models only and 
include a preinstalled outside air kit.

Precautions

Majestic Fireplaces and component parts have been 
highly tested and will operate safely when installed in 
accordance with instructions provided in this manual. 
Carefully read and understand all instructions 

before

 

beginning installation.
If you notice any damage to fireplace or component parts, 
immediately report damage to your Majestic Fireplaces 
dealer.
Only use MHSC components or the warranty will be 
voided and a fire hazard may be created.
MHSC warranty will be voided by and MHSC

 

disclaims 

any responsibility for the following actions:

• 

Installation by any other than a qualified install-
er, preferably NFI or WETT (Canada) certified.

• 

Installation of any damaged fireplace or chim-
ney component;

• 

Modification of fireplace, chimney assembly or 
any component parts thereof; (except for chase 
flashings as detailed in the Chimney Top instal-
lation instructions).

• 

Installation other than as instructed by MHSC; 
or

• 

Installation and/or use of any component part 
not manufactured or approved by MHSC in 
combination or assembly with a Majestic Fire-
places fireplace system, notwithstanding any 
independent testing laboratory or other third 
party approval of such component parts or ac-
cessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in 
compliance 

before 

installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any 
manner. 

Do not install combustible materials on any of the 
black fireplace surround.
Burn only solid wood fuel or gas logs.
Do not install a solid fuel burning insert or other 
products not specified for use with this fireplace.

Proposition 65 Warning: 

Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer 
before installing a television or other electronic de-
vice above this fireplace.

Drafts

The fireplace should not be located in areas that create 
drafts (ie: frequently opened doors and central heating air 
inlets/outlets) that hamper the normal flow of air into the 
fire.

Gas Logs

If you plan to install a gas log, the gas line should be 
installed 

before

 framing the fireplace. The gas line must 

be installed by a certified gas line installer.

STR33 / STR36 / STR42

Listed

UL 127 / ULC-S610

Standard for Factory Built Fireplaces

Safety Information . . . . . . . . . . . . . . . . . .  2
Specifications and Framing   . . . . . . . . . .  3
Parts Identification  . . . . . . . . . . . . . . . . .  4
Chimney Requirements  . . . . . . . . . . . . .  6
Planning Information . . . . . . . . . . . . . . . .  7
Installation   . . . . . . . . . . . . . . . . . . . . . . .  8
Replacement Parts . . . . . . . . . . . . . . . .  20
Accessories   . . . . . . . . . . . . . . . . . . . . .  22

Table of Contents

Содержание STR33

Страница 1: ...Fireplace For Models STR33 STR36 STR42 For use in U S Canada Underwriter s Laboratories Report No MH7603 DO NOT DISCARD THIS MANUAL Retain for future use 7412961 12 08 Rev 19 Homeowner s Installation...

Страница 2: ...mbination or assembly with a Majestic Fire places replace system notwithstanding any independent testing laboratory or other third party approval of such component parts or ac cessory Any such action...

Страница 3: ...added note 9 21 99 Outside Air 14 12 C 12 G F B J 24 Total Unit Width Framing Width Will be 24 Minus 2 x Drywall Thickness 18 STR33 STR36 STR42 A 33 36 42 838mm 914mm 1067mm B 37 40 46 940mm 1016mm 1...

Страница 4: ...STR36 29 17 737 mm 435 mm STR42 35 17 889 mm 435 mm FP1545 Fig 3a Hearth dimensions FP701a STR Parts ID Gas Line Access Outer Dome Outside Air Access Ledge Brackets Header Standoffs Flue Damper Contro...

Страница 5: ...e and chase parts identi cation FP704 STR from FP528 7 28 98 Termination Cap Storm Collar Pan Flashing Draftstop Finish Wall Batt Insulation cut out around restop Firestop Ceiling Level Outer Dome Ref...

Страница 6: ...imney exit STR Series Maximum 90 0 Minimum Without Elbows 15 6 With 2 Elbows 17 6 With 4 Elbows 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a structur...

Страница 7: ...ey to the peak of the roof is 10 3m or less the top of the chimney must be at least 2 610mm above the peak of the roof but never less than 3 914mm in height above the highest point where it passes thr...

Страница 8: ...HEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED Page 14 Fig 20 Installation Chimney Supports The chimney system is supported by the replace for vert...

Страница 9: ...SK8 2 wall chimney systems STR Fireplaces use only model 11CF chimney system Straight Up Chimney Installation To locate the centerline of the ue put the replace in nal position and place a plumb bob f...

Страница 10: ...ves restop spacer model num bers The inside dimension of the frame must be the same as the hole size selected from Figure 12 in order to provide the required air space 1 38 mm with SK8 2 51 mm with Mo...

Страница 11: ...lace are noncombustible Eight 8 nailing anges are supplied with the replace found on the replace hearth To level the box and secure it rmly in place remove the nailing anges from the hearth and instal...

Страница 12: ...space to chimney pipe for ceiling thickness up to 8 203 mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 203mm adjustments must be made in framing to assure...

Страница 13: ...ost portion of chimney sections and any adjacent combustible sur faces Fig 20 Combustible surfaces include burnable materials such as ceiling members joists ooring combustible insulation and roof stru...

Страница 14: ...Firestop Spacers Finishing CAUTION All joints between the nished wall and the replace surround top sides must be sealed with non combustible material to prevent cold air leakage into the room Only no...

Страница 15: ...2 12 305mm Min 12 305mm Max 6 159mm Min FP721 Fig 21 Fireplace surround ush with nished wall Mantel Clearance No Noncombustible Facing Material Finished Wall Standoff 2 x 4 Stud Noncombustible Mate ri...

Страница 16: ...d for the SP40 Rt must 1 85 minimum Examples of wall shield insulation 1 Manville CERAFORM 126 K 27 1 2 inches thick 2 MHSC EH2416 K 458 1 inch thick required FP723 Fig 23 Minimum rebox dimensions fro...

Страница 17: ...material Fig 24 Secure the hearth extension to the oor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the replace hearth and hearth extension...

Страница 18: ...required X of listed thickness K of listed material per inch material Example for Common Brick T new 5 0 0 458 x 0 50 in 5 46 in new required thickness Safety Strips Must be Over lapped 1 2 Min Minimu...

Страница 19: ...OTE When installing an ANSI Z21 11 2 ventless ap pliance the nishing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in replace should be rated le...

Страница 20: ...embly two per replace 3049122 3030126 3032112 5 Screen Assembly four per replace 7554338 7554338 7554340 6 Screen Pulls four per replace 5584139 5584139 5584139 7a Firebrick Hearth 3100103 3102103 310...

Страница 21: ...ssories for this appliance are available from your local Majestic Fireplaces distributor Should you need additional information beyond what your distributor can furnish contact MHSC 149 Cleveland Driv...

Страница 22: ...a square cap Adaptor required Square Termination Top housing with simulated brick pattern T20B Red Tan or Black Proper adapter must be used Includes ashing Adapter Required adapters for T20B top hous...

Страница 23: ...tact AIS SK SK8 with the chimney system FS2100 HT 11CF U S Chimney Components cont d Model Number Description Component Attic Insulation Shield Used to prevent insulation from coming in AIS SK SK8 con...

Страница 24: ...ect safe operation We do not warrant this replace to be in compliance with your local building code Building codes vary greatly throughout the country and you should determine whether your local build...