Majestic • RUBY25IN, RUBY25IL, RUBY30IN, RUBY30IL, RUBY35IN, RUBY35IL Owner’s Manual • 2542-981 Rev. K • 5/21
Figure 3.6
Glass Seal Plate
GLASS SEAL PLATE
GLASS SEAL
PLATE INSTALLED
H. Heat Management
Heat Output
Heat output may be controlled on the RUBY-IFT model
by adjusting the “FLAME” setting and “FAN” setting on
the RC-400 remote control.
NOTICE!
Set the fan speed to high on the RC400
remote control during the first three to four hours of
break-in operation. See Section G. This break-in
will ensure optimum speed control of the fan during
subsequent use.
G. Appliance Break-In
NOTICE!
Open windows for air circulation during fire
-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
Follow the initial break-in procedure below to cure the
materials used to manufacture the fireplace and the
finishing materials around it.
• The fireplace should be run three to four hours
continuously on high.
• Turn the fireplace off and allow it to cool completely.
• Remove fixed glass assembly. See Section 4.B.
• Clean fixed glass assembly. See Section 4.B.
• Verify Glass Seal Plate is properly installed. See Figure
3.6.
WARNING!
Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monox
-
ide exposure.
• Replace the fixed glass assembly.
Note:
Some installations may require additional run time
to cure. If odors persist after the initial break-in period,
run the fireplace for an additional three to four hours
continuously on high.
Note:
Some IPI systems have a safety feature that
automatically shuts down the fireplace after 9 hours of
continuous operation without receiving a command from
the remote control. If this occurs, restart the appliance.
• Verify collar slide plate screw is attached see Figure 3.5.