Removing Fixed Glass Assembly

WARNING! 

Risk  of Asphyxiation! 

Handle  fixed  glass 

assembly  with  care.  Inspect  the  gasket  to  ensure  it  is 

undamaged  and  inspect  the  glass  for  cracks,  chips  or 

scratches. 

• 

DO NOT

 

strike, slam or scratch glass.

• 

DO NOT

 

operate fireplace with glass removed, cracked, 

broken, or scratched.

 

•  

Replace as a complete assembly.

•  

The  glass  assembly  fastens  to  the  fireplace  in  four 

places. The four fastening mechanisms are spring-

loaded glass latches.  An example of the glass latch is 

shown in Figure 4.2.  

•  To release glass assembly, use the supplied multi-

purpose tool.  See Figure 4.1.

 

 While supporting the 

glass assembly, pull the two bottom spring-loaded 

latches forward and allow them to retract away from the 

glass assembly.  Tilt the bottom of the glass assembly 

outward until the top latches disengage.

•  Clean glass with a non-abrasive commercially available 

cleaner.

-  Light deposits: Use a soft cloth with soap and water.
-  Heavy deposits: Use commercial fireplace glass 

cleaner (consult with your dealer).

Figure 4.2  Fixed Glass Assembly

Figure 4.1  Multi-Purpose Tool

Replacing Fixed Glass Assembly

•  Verify Glass Seal Plate is properly installed.  See Figure 

4.3.

WARNING!

 Glass seal plate must be properly installed. 

Risk of elevated component temps and carbon monox

-

ide exposure.  

•   Tilt the top of the glass assembly toward fireplace and 

slide glass assembly upward to engage top latches. 

Verify top latches are fully engaged and then fasten the 

two bottom latches using the supplied mulit-purpose tool. 

•  Reinstall door or decorative barrier front.

GLASS CLIPS

Figure 4.3  Glass Seal Plate

 GLASS SEAL PLATE

 GLASS SEAL 

 PLATE INSTALLED

Содержание RUBY25IN

Страница 1: ...ing Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Ins...

Страница 2: ...fuel Ne Ne doit doit pas entre entre utilise utilise avec avec un un combustible combustible solide solide This This appliance appliance must must be be installed installed in in accordance accordance...

Страница 3: ...equency and Tasks 17 B Maintenance Tasks Homeowner 17 C Maintenance Tasks Qualified Service Technician 20 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions 22 B Frequently...

Страница 4: ...dependent authorized HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless...

Страница 5: ...handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not suppl...

Страница 6: ...factored as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI...

Страница 7: ...the off position and remove batteries 3 3 Important Safety and Operating Information Clear Space WARNING DO NOT place combustible objects in front of the fireplace or block louvers High temperatures...

Страница 8: ...NTEL FIXED GLASS ASSEMBLY SECTION 4 B HEARTH CLEAR SPACE SECTION 3 A ACCESS TO BATTERY BACKUP SECTION 3 I FAN KIT SECTION 3 H 3 J REMOTE CONTROL SECTION 6 C MEASUREMENTS FROM TOP OF THE SURROUND OPENI...

Страница 9: ...be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures iden fied in the TV s t...

Страница 10: ...terial and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Verify Glass Seal Plate is properly installed See Figure 3 6 WARNING Glass...

Страница 11: ...p plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn...

Страница 12: ...materials used to manufacture the fireplace and the finishing materials around it The fireplace should be run three to four hours continuously on high Turn the fireplace off and allow it to cool compl...

Страница 13: ...IFT RC150 Wireless Wall Switch Toggle the switch as you would under normal circumstances Ignition Module Access to the control cavity See Figure 3 3 will require the decorative barrier front glass pa...

Страница 14: ...phones and other portable devices NOTICE Some power banks and many USB battery packs may switch off if the current being drawn is too low IF this is the case different low power devices such as a cell...

Страница 15: ...tment in flame height is possible Remote Position The remote position allows operation of the appliance from a wired wall switch IFT RC400 or IFT RC150 remote controls The IFT ECM switch must be in th...

Страница 16: ...t switch to the off position See Figure 3 10 for reset switch location or Set the IFT ECM 3 position selector switch to OFF position Wait five 5 minutes to allow possible accumulated gas to clear Togg...

Страница 17: ...ouble shooting and service for your appliance Visit www ma jesticproducts com to locate a dealer We recommend annual service by a qualified service technician Glass Cleaning Frequency Seasonally By Ho...

Страница 18: ...tches forward and allow them to retract away from the glass assembly Tilt the bottom of the glass assembly outward until the top latches disengage Clean glass with a non abrasive commercially availabl...

Страница 19: ...ay Access GLASS SEAL PLATE BASE REFRACTORY GLASS CLIP ASSEMBLIES GLASS CLIP ASSEMBY SCREW ACCESS Note Bottom right glass clip on 25 inch models must be removed to gain access to controls GLASS SEAL PL...

Страница 20: ...enting and termination cap for blockage or obstruction such as plants bird nests leaves snow debris etc Verify termination cap clearance to subsequent construc tion building additions decks fences or...

Страница 21: ...delay Inspect and ensure the lighting of the main burner occurs within four seconds of the main gas valve opening Inspect for lifting or other flame problems Verify air shutter setting is correct See...

Страница 22: ...ation Manual Section 7 Venting Odor from appliance When first operated this appliance may release an odor for the first several hours This is caused by the curing of the paint and the burning off of a...

Страница 23: ...difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperatu...

Страница 24: ...o AC power AC DC adaptor faulty backup batteries if being used depleted IFT ECM slider switch in OFF position Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junctio...

Страница 25: ...ected to green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not li...

Страница 26: ...non listed accessories could result in a safety hazard and will void the warranty Required Decorative Barrier Front Sur round This appliance requires a Surround Decorative Barrier Front For available...

Страница 27: ...40 711 2 Log 2 SRV2542 715 3 Log 3 SRV2540 713 4 Log 4 SRV2542 712 5 Log 5 SRV2542 714 6 Log 6 SRV2542 717 7 Log 7 SRV2542 717 8 Slide Plate Assembly 2532 014 Tool Slide Plate Multi purpose 2532 140 G...

Страница 28: ...711 2 Log 2 SRV2544 715 3 Log 3 SRV2542 712 4 Log 4 SRV2542 715 5 Log 5 SRV2542 717 6 Log 6 SRV2542 714 7 Log 7 SRV2542 717 8 Log 8 SRV2542 718 9 Slide Plate Assembly 2532 014 Tool Slide Plate Multi...

Страница 29: ...2 SRV2544 715 3 Log 3 SRV2544 712 4 Log 4 SRV2544 716 5 Log 5 SRV2542 717 6 Log 6 SRV2542 717 7 Log 7 SRV2542 717 8 Log 8 SRV2540 713 9 Log 9 SRV2540 713 10 Slide Plate Assembly 2532 014 Tool Slide P...

Страница 30: ...315 5 Y 20 6 Gasket Valve Plate RUBY25 2531 131 RUBY30 RUBY35 2532 131 20 7 Gasket Bulkhead 438 407 20 8 Bulkhead w Flex Tube SRV7000 156 Y Orifice NG 40C RUBY25 582 840 Y Orifice Propane 53C 582 853...

Страница 31: ...istributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Battery Pack Pre LC5673022 SRV2326 134 Y Post LC5673022 SRV2326 142 Bolt Level Leg Qty 4 req 2073 162 24 Y Mineral Wool 050 721 RC400...

Страница 32: ..._________________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with part...

Отзывы: