Glass Cleaning

Frequency: 

Seasonally

By: 

Homeowner

Tools  Needed

:    Protective  gloves,  gas  fireplace  glass 

cleaner, drop cloth and a stable work surface.

CAUTION! 

Handle  fixed  glass  assembly  with  care. 

Glass is breakable.

•  Avoid striking, scratching or slamming glass

• 

DO NOT

 use abrasive cleaners

• 

DO NOT

 clean glass while it is hot

 

Prepare a work area large enough to accommodate fixed 

glass assembly and decorative barrier front by placing a 

drop cloth on a flat, stable surface.

Note

: Fixed glass assembly and gasketing may have res

-

idue that can stain carpeting or floor surfaces.

 

Remove decorative barrier front from fireplace and set  

aside on work surface.

B.  Maintenance Tasks - Homeowner

The  following  tasks  may  be  performed  annually  by  the 

homeowner.  If you are uncomfortable performing any of 

the listed tasks, please call your dealer for a service ap

-

pointment.
More frequent cleaning may be required due to excessive 

lint from carpeting, bedding material, etc. It is imperative 

that control compartments, burners and circulating air 

passageways of the appliance be kept clean.  Any safety 

screen, guard, or barrier removed for servicing the appli-

ance must be replaced prior to operating the appliance.

CAUTION! Risk of Burns! 

The fireplace shall be turned 

off and cooled before servicing. 

When  properly  maintained,  your  fireplace  will  give  you 

many years of trouble-free service.  

Contact your dealer 

to answer questions regarding proper operation, trouble-

shooting and service for your appliance.  Visit www.ma-

jesticproducts.com to locate a dealer.  We recommend 

annual service by a qualified service technician. 

IMPORTANT!   Any  safety  screen,  decorative  barrier  front  

or guard removed for servicing must be replaced prior to 

operating the fireplace.

Installation and repair should be done by a qualified service 

technician only. The appliance should be inspected before 

use and at least annually by a professional service person. 

Maintenance and Service 

Task

Frequency

To be completed by

Glass Cleaning

Seasonally 

Homeowner

Decorative Barrier 

Fronts

Annually

Optional Remote 

Control

Seasonally

Termination Cap

Seasonally

Gasket Seal and 

Glass Assembly 

Inspection

Annually

Qualified Service 

Technician

Log Inspection 

Annually 

Firebox Inspection

Annually

Control 

Compartment &  

Firebox Top

Annually

Pilot and Burner 

Ignition and 

Operation

Annually

Interior Ceramic 

Glass Panel 

Cleaning

Seasonally

Electrical Service 

and Repair

As needed

A.  Maintenance:  Frequency and Tasks

Figure 4.1  Fixed Glass Assembly

GLASS

ASSEMBLY

LATCHES

(BOTH BOTTOM 

AND TOP)

GLASS FRAME 

TABS

Содержание MER42MN

Страница 1: ...ified kit is used DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NO...

Страница 2: ...e ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 le Cet appareil doit tre install conform ment aux codes locaux s il y a lieu sinon suivez National Fuel Gas Code ANSI...

Страница 3: ...Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall and Mantel Temperatures 8 E...

Страница 4: ...from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years from the...

Страница 5: ...r handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supp...

Страница 6: ...roved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential heating calculations NOTICE This installation must conform with local code...

Страница 7: ...t your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire place for an extended period o...

Страница 8: ...standards Combustible Mantel and Surfaces around a Fireplace The allowable temperature rise above ambient is 117 F for all exposed combustible surfaces around the fireplace including the mantel when...

Страница 9: ...9 Majestic MER36MN MER42MN Owner s Manual 2599 981 Rev B 5 23 G Lighting Instructions IPI...

Страница 10: ...ll divert heat outside the home building and or a Passive Heat kit which dis perses the heat into the same room as the fireplace Refer to Section 6 of the appliance installation manual to confirm whic...

Страница 11: ...liance See Figure 3 3 for location The decorative barrier front and front refractory may need to be removed 2 Insert four AA cell batteries into battery tray Battery polarity must be correct or module...

Страница 12: ...No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a wired wall switch IFT RC400 or IFT RC150 remote controls The IFT ECM switch must...

Страница 13: ...use the paired IFT RC400 IFT RC150 or wired wall switch to start the appliance appliance will ignite normally if the error condition was corrected If the IFT ECM re enters the lock out condition afte...

Страница 14: ...ust be replaced prior to operating the appliance CAUTION Risk of Burns The fireplace shall be turned off and cooled before servicing When properly maintained your fireplace will give you many years of...

Страница 15: ...place as necessary Inspect for scratches dents or other damage and repair as necessary Check that air intake and discharge areas are not blocked Vacuum and dust surfaces Optional Remote Control Freque...

Страница 16: ...ssary Firebox Inspection Frequency Annually By Qualified Service Technician Tools needed Protective gloves sandpaper steel wool cloths mineral spirits primer and touch up paint Inspect for paint condi...

Страница 17: ...appliance installation manual for proper ember placement Check for smooth lighting and ignition carryover to all ports Verify that there is no ignition delay Inspect and ensure the lighting of the ma...

Страница 18: ...hing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the curing...

Страница 19: ...een the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the remot...

Страница 20: ...tion box and ECM Verify AC DC adaptor out put voltage is between 5 7 6 3 Vdc If battery pack is used check battery pack voltage is 4 2 V if not replace batteries Shorted or loose connection in system...

Страница 21: ...valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5...

Страница 22: ...ection 2 A in appliance Installation Manual Options Remote Controls Wall Controls and Wall Switches IFT RC150 MAJ IntelliFire Touch wireless wall switch IFT RC400 IntelliFire Touch remote control Inte...

Страница 23: ...mbly 2584 007 Y 3 Base Pan Assembly 2584 017 4 Media Bracket 2584 141 5 Pilot Shield 2584 139 6 Glass Assembly GLA 6KL Y Finishing Strips Sold as set only SRVFS 6K 7 Surround SRV2583 019 Surround Bott...

Страница 24: ...Assembly 2588 007 Y 3 Base Pan Assembly 2588 017 4 Media Bracket 2584 141 5 Pilot Shield 2584 139 6 Glass Assembly GLA 8KL Y Finishing Strips Sold as set only SRVFS 8K 7 Surround SRV2587 019 Surround...

Страница 25: ...DESCRIPTION COMMENTS PART NUMBER 9 1 Pilot Assembly NG 2106 169 Y 9 2 Flex Ball Valve Assembly SRV302 320 Y 9 3 Valve NG SRV2166 302 Y 9 4 Male Connector Pkg of 5 303 315 5 Y 9 5 Battery Holder SRV23...

Страница 26: ...83 063 Y 9 6c Component Tray 2279 185 9 6d Thermostat Wire Assembly SRV2118 170 Y 9 6e Transformer 6 Volt Wall SRV2326 131 Y Driftwood Logs Optional LOGS KMOD Stone Kit Optional Qty 3 req STONES NATUR...

Страница 27: ...______________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for u...

Отзывы: