background image

Majestic  •  MER36MN, MER42MN Owner’s Manual  •  2599-981 Rev. B  •  5/23

12

K.  Detailed Component Operating 

Instructions -  IntelliFire Touch

IFT-ECM Detailed Operating Instruction

Figure 3.4   IFT-ECM

3 POSITION SWITCH

TOP VIEW

LED INDICATOR

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

4.  An IFT-ECM reset is required if the module is in a 

lock-out condition.  When this occurs, the appliance 

is shut down and the IFT-ECM status indicator LED 

will be blinking a RED/GREEN error code along with a 

one-time audible double- beep.  If the IFT-ECM is in a 

lock-out condition, refer to the troubleshooting chart to 

interpret the error code and take corrective action as 

required.  To reset the IFT-ECM after a lock-out error

CAUTION! 

Risk of burns! 

Appliance surfaces are hot 

when  operating  and  during  cool  down.  Use  care  and 

wear gloves when opening the front and accessing com-

ponents inside the appliance.

 

       -  Be aware the appliance may be HOT, use  

          care in accessing the IFT-ECM. 

1.  The Electronic Control Module (IFT-ECM) has a 

three-position ON/OFF/REMOTE selector switch 

that must be set for proper operation. See Figure 

3.4.  When changing switch positions, it is important 

to pause in each position for 1-2 seconds. 

 

OFF Position:   

 

The appliance will not respond to any commands 

from a wired wall switch, IFT-RC150  or IFT-RC400 

remote controls.  The unit should be in the OFF 

position during service, fuel conversion, and to 

reset the IFT-ECM in the event the system goes 

into a LOCK-OUT mode as the result of a system 

error.  When switched to the OFF position while the 

appliance is operating, the system will shut down. 

 

ON  Position:   

 

The  appliance  will  ignite  and  run continuously at 

the HI flame setting.  No adjustment in flame height 

is possible.  

 

Remote Position:   

 

The remote position allows operation of the 

appliance from a wired wall switch, IFT-RC400 or 

IFT-RC150 remote controls.  The IFT-ECM switch 

must be in this position to pair the IFT-ECM with the 

IFT-ACM (if installed), and/or IFT-RC400 and IFT-

RC150 remote controls.  See the IFT-RC400 or IFT-

RC150 installation manual for detailed instructions 

on pairing the IFT-ECM with the remote controls. 

After successfully pairing a IFT-RC400, all installed 

accessories can be controlled by the IFT-RC400 

(see IFT-RC400 user manual).  The  RC150 allows 

the user to turn ON/OFF the flame in the appliance 

and activate the Cold Climate mode if desired.  The 

IFT-ECM has a safety feature that will automatically 

shut down the fireplace after 9 hours of continuous 

operation without receiving a command from the 

IFT-RC400 or IFT-RC150. 

2.  If multiple control options are installed, the IFT-ECM 

will respond to the last command from the wired wall 

switch, IFT-RC400 or IFT-RC150.  The wired wall 

switch is NOT available if a Power Vent is used.

The IFT-ECM has a safety feature that will 

automatically  shut  down  the  fireplace  after 

9 hours of continuous operation in the ON 

position, except when operated in active 

thermostat mode.  

The Pilot button on the IFT-ECM activates the Cold 

Climate function of the fireplace.  This function lights 

the pilot flame ONLY to provide enough heat in the 

firebox to reduce condensation in cool, high humidity 

ambient conditions.  To activate the Cold Climate 

press and hold the Pilot button for one second and  

release.  The IFT-ECM will flash two green LED blinks, 

 

beep twice and light and rectify the pilot flame when 

 

pressed to activate.  To turn off Cold Climate, press 

 

and hold the Pilot button for one second and release.   

The IFT-ECM will flash one green LED blink, beep once 

 

and shut down the pilot flame.  If remote controls are 

 

paired with the IFT-ECM, this feature can also be  

activated with the IFT-RC400 and/or IFT-RC150.  The 

cold climate function will turn off after seven days of 

continuous operation.

The IFT-RC400 and IFT-RC150 remotes are an option 

for this model.  The IntelliFire Wi-Fi module (IFT-WFM) is 

also an option.

Содержание MER42MN

Страница 1: ...ified kit is used DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NO...

Страница 2: ...e ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 le Cet appareil doit tre install conform ment aux codes locaux s il y a lieu sinon suivez National Fuel Gas Code ANSI...

Страница 3: ...Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall and Mantel Temperatures 8 E...

Страница 4: ...from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years from the...

Страница 5: ...r handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supp...

Страница 6: ...roved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential heating calculations NOTICE This installation must conform with local code...

Страница 7: ...t your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire place for an extended period o...

Страница 8: ...standards Combustible Mantel and Surfaces around a Fireplace The allowable temperature rise above ambient is 117 F for all exposed combustible surfaces around the fireplace including the mantel when...

Страница 9: ...9 Majestic MER36MN MER42MN Owner s Manual 2599 981 Rev B 5 23 G Lighting Instructions IPI...

Страница 10: ...ll divert heat outside the home building and or a Passive Heat kit which dis perses the heat into the same room as the fireplace Refer to Section 6 of the appliance installation manual to confirm whic...

Страница 11: ...liance See Figure 3 3 for location The decorative barrier front and front refractory may need to be removed 2 Insert four AA cell batteries into battery tray Battery polarity must be correct or module...

Страница 12: ...No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a wired wall switch IFT RC400 or IFT RC150 remote controls The IFT ECM switch must...

Страница 13: ...use the paired IFT RC400 IFT RC150 or wired wall switch to start the appliance appliance will ignite normally if the error condition was corrected If the IFT ECM re enters the lock out condition afte...

Страница 14: ...ust be replaced prior to operating the appliance CAUTION Risk of Burns The fireplace shall be turned off and cooled before servicing When properly maintained your fireplace will give you many years of...

Страница 15: ...place as necessary Inspect for scratches dents or other damage and repair as necessary Check that air intake and discharge areas are not blocked Vacuum and dust surfaces Optional Remote Control Freque...

Страница 16: ...ssary Firebox Inspection Frequency Annually By Qualified Service Technician Tools needed Protective gloves sandpaper steel wool cloths mineral spirits primer and touch up paint Inspect for paint condi...

Страница 17: ...appliance installation manual for proper ember placement Check for smooth lighting and ignition carryover to all ports Verify that there is no ignition delay Inspect and ensure the lighting of the ma...

Страница 18: ...hing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the curing...

Страница 19: ...een the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the remot...

Страница 20: ...tion box and ECM Verify AC DC adaptor out put voltage is between 5 7 6 3 Vdc If battery pack is used check battery pack voltage is 4 2 V if not replace batteries Shorted or loose connection in system...

Страница 21: ...valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5...

Страница 22: ...ection 2 A in appliance Installation Manual Options Remote Controls Wall Controls and Wall Switches IFT RC150 MAJ IntelliFire Touch wireless wall switch IFT RC400 IntelliFire Touch remote control Inte...

Страница 23: ...mbly 2584 007 Y 3 Base Pan Assembly 2584 017 4 Media Bracket 2584 141 5 Pilot Shield 2584 139 6 Glass Assembly GLA 6KL Y Finishing Strips Sold as set only SRVFS 6K 7 Surround SRV2583 019 Surround Bott...

Страница 24: ...Assembly 2588 007 Y 3 Base Pan Assembly 2588 017 4 Media Bracket 2584 141 5 Pilot Shield 2584 139 6 Glass Assembly GLA 8KL Y Finishing Strips Sold as set only SRVFS 8K 7 Surround SRV2587 019 Surround...

Страница 25: ...DESCRIPTION COMMENTS PART NUMBER 9 1 Pilot Assembly NG 2106 169 Y 9 2 Flex Ball Valve Assembly SRV302 320 Y 9 3 Valve NG SRV2166 302 Y 9 4 Male Connector Pkg of 5 303 315 5 Y 9 5 Battery Holder SRV23...

Страница 26: ...83 063 Y 9 6c Component Tray 2279 185 9 6d Thermostat Wire Assembly SRV2118 170 Y 9 6e Transformer 6 Volt Wall SRV2326 131 Y Driftwood Logs Optional LOGS KMOD Stone Kit Optional Qty 3 req STONES NATUR...

Страница 27: ...______________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for u...

Отзывы: