background image

1

Majestic  •  MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual  •  2205-980 Rev. H  •  12/16

Installation Manual

Installation and Appliance Setup

INSTALLER:  Leave this manual with party responsible for use and operation.
OWNER:  Retain this manual for future reference.

NOTICE: DO NOT

 discard this manual!

In the Commonwealth of Massachusetts installation must be 
performed by a licensed plumber or gas 

fi

 tter.

See Table of Contents for location of additional Commonwealth 
of Massachusetts requirements.

Models: MDVI30IN
               MDVI35IN
          MDVI30IL
             MDVI35IL

This appliance may be installed as an OEM 
installation in manufactured home (USA 
only) or mobile home and must be installed 
in accordance with the manufacturer’s 
instructions and the 

Manufactured Home 

Construction and Safety Standard,

 

Title 24 

CFR, Part 3280 

in the United States, or the 

Standard for Installation in Mobile Homes, 
CAN/CSA Z240 MH Series,

 in Canada.

This appliance is only for use with the type(s) 
of gas indicated on the rating plate. This 
appliance is not convertible for use with other 
gases, unless a certi

fi

 ed kit is used.

• 

DO NOT

 store or use gasoline or other 

fl

 am-

mable vapors and liquids in the vicinity of this 

or any other appliance.

•  What to do if you smell gas   

DO NOT

 try to light any appliance.

DO NOT

 touch any electrical switch. 

DO 

NOT

 use any phone in your building.

-  Leave the building immediately.
-  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

-  If you cannot reach your gas supplier, call 

the 

fi

 re department.

•  Installation and service must be performed 

by a quali

fi

 ed installer, service agency, or the 

gas supplier.

WARNING: 

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage. 

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

A barrier designed to reduce the risk of 
burns from the hot viewing glass is provided 
with this appliance and shall be installed for 
the protection of children and other at-risk 
individuals.

RUBY
SERIES

Содержание MDVI30IN

Страница 1: ...ith the type s of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used DO NOT store or use gasoline or other flam mable vapors an...

Страница 2: ...e Requirements A Minimum Fireplace Opening 8 B Mantel and Wall Projections 10 5 Termination Location and Vent Information A Vent Termination Minimum Clearances 11 6 Installation Preparation A Cleaning...

Страница 3: ...onversion performed ___________________________ Leak check performed and inlet pressure veri ed ___________________________ Veri ed proper air shutter setting for installation type ___________________...

Страница 4: ...al Provincial State and local building codes Fireplaces are to be constructed of non combustible materials and in the absence of local or regional codes meet criteria of NFPA211 No additional outside...

Страница 5: ...y or property damage For assistance or additional information consult a qualified service technician service agency or your dealer B Tools and Supplies Needed Before beginning the installation be sure...

Страница 6: ...s Millimeters Inches Millimeters A 23 7 16 595 20 3 16 513 B 34 5 8 879 30 5 8 778 C 31 5 8 803 27 1 2 699 D 15 11 16 398 12 3 16 310 E 24 1 16 611 20 7 16 519 F 21 1 8 537 17 5 8 448 G 15 11 16 398 1...

Страница 7: ...ons CRDI30BK CRDI30BZ CRDI35BK CRDI35BZ DECORATIVE FRONTS CRDI30BK CRDI30BZ CRDI35BK CRDI35BZ A B C D E F G MDVI30IN IL CRDI30BK CRDI30BZ in 29 13 13 16 4 1 2 36 23 1 2 23 1 2 mm 737 351 114 914 597 5...

Страница 8: ...rts of the fireplace in which the gas fireplace insert is to be installed is prohibited except the floor as tested for and as noted above and in Figure 4 1 A minimum 1 2 inch gap from the bottom of th...

Страница 9: ...ed for installation C D B A E F MINIMUM FIREBOX OPENING Location MDVI35IN IL MDVI30IN IL Inches Millimeters Inches Millimeters A Rear Width 24 610 20 3 4 527 B Front Width 35 1 8 892 31 1 8 791 C Heig...

Страница 10: ...or outer wrap of factory built firebox Combustible facings must not extend behind the insert surround For non combustible material specifications refer to Section 1 E Figure 4 4 Mantel Clearances 12...

Страница 11: ...21 12 8 0 Figure 5 1 Minimum Height From Roof To Lowest Discharge Opening HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING 2 FT MIN 20...

Страница 12: ...ing needs D Fireplace Conversion Notice Permanently attach the label with the following warning to the inside lower back of the fireplace firebox into which the insert is being installed Silicone or m...

Страница 13: ...Run Length 14 ft Maximum Vertical Run Length 50 ft CAUTION ALL vent specifications MUST be followed This product is tested and listed to these specifications Appliance performance will suffer if speci...

Страница 14: ...F silicone on flue tile top C Connecting Vent Pipe Reference instructions in the termination kit Install the 3 inch flexible vent pipe s down through the chimney Secure the exhaust flexible vent pipe...

Страница 15: ...e 7 3 Remove both screws that secure the leveling leg to the side of the appliance Turn the leveling leg around so that the foot is facing out and downward Line up the two holes on the leg with the ho...

Страница 16: ...8 12 to 20 12 7 5 Over 20 12 to 21 12 8 0 HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING 2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT...

Страница 17: ...ENT PIPE Note Untwist the pipe while extend ing it to achieve full 30 length OR Note The LINK DV4 30B and LINKSQ DV4 30 systems REQUIRE this insulation To prevent odors and cold air drafts it may be n...

Страница 18: ...ts IntellifireTM Plus Ig nition System Wiring Wire an outlet box 110 120 VAC in the bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly or the...

Страница 19: ...done now to avoid reconstruction Follow instructions that come with those accessories Plug the cord into a convenient outlet Must use cord supplied An IntelliFire Plus Wireless Controls or WSK 21 wire...

Страница 20: ...ing shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WARNING Risk of Fire or Explosion High pressure will damage valve Low pressure may...

Страница 21: ...lified ser vice technician at the time of installation The air shutter is set at the factory for minimum vertical vent run Adjust air shutter for longer vertical runs See Figure 9 1 NOTICE If sooting...

Страница 22: ...crete board etc Clearance to combustible material under the insert is 1 4 inch 6 mm Clearance from top of fireplace opening for combustibles extending 12 inches max is 12 inches Use leveling legs to r...

Страница 23: ...glass latch is shown in Figure 11 1 To release glass assembly pull the two bottom spring loaded latches forward and allow them to retract away from the glass assembly Slide the glass assembly outward...

Страница 24: ...er the port holes not pressed down on or into the holes Create a single layer no more than 1 4 inch thick Failure to follow this procedure will likely cause lighting and sooting problems Save the rema...

Страница 25: ...sary See Figure 3 Position Log 1 as shown in Figure 5 Place the slots on the bottom of the log over the basepan tabs See Figure 4 for slot detail Figure 5 Log 1 Installed Figure 1 Log Set Components L...

Страница 26: ...ee Figure 8 Position Log 3 as shown in Figure 9 by mating the hole on the bottom of Log 3 with the last log pin on the surface of the burner adjusting placement on the grate tine as necessary for corr...

Страница 27: ...n Log 1 and Log 3 The end of the log will contact the back wall of the firebox Log 6 SRV2219 706 Note the grate tine groove as shown in Figure 13 and the flat area highlighted in Figure 9 Position Log...

Страница 28: ...3 Position Log 1 as shown in Figure 5 Place the slots on the bottom of the log over the basepan tabs See Figure 4 for slot detail Figure 5 Log 1 Installed LOG 1 SRV2218 701 LOG 1 SRV2218 701 LOG 2 SRV...

Страница 29: ...Log 3 Position Log 3 as shown in Figure 9 by mating the hole on the bottom of Log 3 with the last log pin on the surface of the burner adjusting placement on the grate tine as necessary for correct or...

Страница 30: ...should rest fully on the grate Rest the log in the flat area on Log 2 GRATE TINE GROOVE GRATE TINE GROOVE Figure 13 Log 5 Detail Log 6 SRV2218 706 Note the locations of the flat areas on Log 1 and Log...

Страница 31: ...ions WARNING Risk of Fire Install ONLY doors or fronts approved by Hearth Home Technologies Unapproved doors or fronts may cause fireplace to overheat This fireplace has been supplied with an integral...

Страница 32: ...LINKSQC DV4 30 LINKSQB DV4 30 Masonry 3 inch flex liner kit Expands to 30 feet and 4 feet respectively Includes two liners termination cap and flashing Figure 12 1 Direct Vent Flex Liner Kits Figure 1...

Страница 33: ...nearest Majestic dealer please visit www majesticproducts com Remote Controls Wall Controls and Wall Switches An RC200 remote control system is included with this ap pliance After a qualified service...