27
Vermont Castings Majestic Products DV360/580 Series
20002261
LED Count
Service Action
8
Replace valve
7
Confirm stepper motor connection
exists
5
Confirm fan connection exists and
works
4
Confirm gas type; jumper in place
3
Replace thermopiles
2
Turn fan ON
NOTE: Some keys are not active.
2. Slide the Remote/Local switch to REMOTE and
teach the valve a transmitter (refer to Item 6, page
1). The Error Code will clear itself after approxi-
mately 1
¹⁄₂
minutes and return to normal operation.
If the setting is above
room temperature on
the transmitter, does the
main valve and fan turn
on?
If the setting is below
room temperature on
the transmitter, does
the main valve and fan
turn off?
Turn pilotstat knob to
OFF to turn valve
completely off
Auto Path
Yes
Yes
No
If the manual switch is
set to REMOTE, press
the mode button to
display AUTO on the
transmitter. Does the
transmitter display the
room and temperature
setting?
Move switch from
LOCAL to RE-
MOTE. Press any
key within 30
seconds.
No